![Glow-worm 38cxi Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/glow-worm/38cxi/38cxi_instructions-for-use-installation-and-servicing_2234477034.webp)
35
2000225065A
14 Replacement of Parts
14.1 General
Replacement of parts must be carried out by a competent
person.
Before replacing any parts the boiler should be isolated from the
mains electric supply and the gas should be turned off at the
service cock on the boiler, see diagram 8.1.
Unless stated otherwise parts are replaced in the reverse order
to removal.
After replacing any parts always test for gas soundness and if
necessary carry out functional test of the controls.
For replacement of parts the front casing and the inner casing
panel of the boiler will need to be removed. To remove undo the
two screws on the underside of the front casing and lift off. Undo
the two screws on the front of the inner front panel and lift off.
The side panels can be hinged sideways to aid replacement of
parts.
To hinge a side panel undo and remove the three screws
securing each side panel to the boiler, two at the front and one
at the top.
14.2 Spark Electrode
For access, refer to section 14.1.
Remove the spark plug lead, earth lead and two securing
screws. Withdraw the spark electrode carefully from the
combustion chamber, see diagram 12.2.
14.3 Igniter Unit
For access, refer to section 14.1.
Remove ignition lead and electrical connections then remove
igniter unit by removing two securing screws, see diagram 14.1.
14.4 Ignition Lead
For access, refer to section 14.1.
Refer to diagram 12.5.
Pull the spark plug style connector off the spark electrode and
the spade connector connected to the igniter unit,
see diagram 14.1.
14.5 DC Fan supply
For access, refer to section 14.1.
Refer to diagram 14.2.
Unplug white plastic plug from the DC fan supply.
Drop down control panel to the service position, see diagram
12.13.
Undo the three screws securing rear cover and lift off.
Unplug DC fan supply lead from main PCB, see diagram 14.3.
Release cable grip located on boiler case.
Remove DC fan supply cable from retaining clip located to the
right of cable grip.
Undo the two screws securing DC fan supply.
Hinge right hand side panel, refer to relevant part of section
14.1.
Remove DC fan supply and lead.
Diagram 14.3
MAIN PCB
Diagram 14.2
DC FAN
SUPPLY
11420
PLUG
CABLE
GRIP
SECURING
SCREW
(2)
Diagram 14.1
IGNITER UNIT
IGNITION
LEAD
ELECTRICAL
CONNECTIONS
SECURING
SCREWS (2)
SPADE
CONNECTOR
COVER
SECURING
SCREWS
DC FAN SUPPLY
CONNECTION
FUSE
RETAINING CLIPS
11491
11492