15  Manual Handling 

IMPoRTanT. 

With regards to the Manual Handling Operations, 1992 

Regulations, the following lift operation exceeds the recommended 

weight for a one man lift.

General recommendations when handling

Clear the route before attempting the lift.

Ensure safe lifting techniques are used – keep back straight – bend 

using legs. Keep load as close to body as possible. Do not twist – 

reposition feet instead. If 2 persons performing lift, ensure co-ordinat-

ed movements during lift. Avoid upper body/top heavy bending - do 

not lean forward/sideways. Recommend wear suitable cut resistant 

gloves with good grip to protect against sharp edges and ensure good 

grip.

Always use assistance if required.

Removal of carton from delivery van

Recommend 2 person lift or 1 person with use of sack truck.  If 1 

person is performing lift, straddle the load, tilt and place carton into 

position on truck.  Recommend secure appliance onto truck with 

suitable straps.  Ensure safe lifting techniques are used – keep back 

straight – bend using legs. Keep load as close to body as possible.  If 

2 persons performing lift, ensure co-ordinated movements during lift. 

Always use assistance if required.

Carriage of carton from point of delivery to point of installation – 

ground floor.

Recommend 2 person lift or 1 person with use of sack truck. If 1 per-

son is performing lift, straddle the load, tilt and place carton into posi-

tion on truck.  Recommend secure appliance onto truck with suitable 

straps.  Ensure safe lifting techniques are used – keep back straight – 

bend using legs. Keep load as close to body as possible.  If 2 persons 

performing lift, ensure co-ordinated

 

movements during lift.  Clear the 

route before attempting the lift.  If removing boiler from truck straddle 

the load and tilt forwards to facilitate secure grip.  Ensure safe lifting 

techniques are used – keep back straight – bend using legs.  Do not 

twist – reposition feet instead.  Take care to

 

avoid trip hazards, slip-

pery or wet surfaces and when climbing steps and stairs.  Always use 

assistance if required.

Carriage of carton from point of delivery to point of installation – 

first or higher floor, cellar.

Recommend 2-person lift or 1 person with use of sack truck. If 1 

person is performing lift, straddle the load, tilt and place carton into 

position on truck.  Recommend secure appliance onto truck with 

suitable straps.  Ensure safe lifting techniques are used – keep back 

straight – bend using legs. Keep load as close to body as possible.  If 

2 persons performing lift, ensure co-ordinated movements during lift. 

Avoid upper body/top heavy bending - do not lean forward/sideways.  

Clear the route before attempting the lift.  If removing boiler from truck 

straddle the load and tilt forwards to facilitate secure grip. Ensure safe 

lifting techniques are used – keep back straight – bend using legs.  

Do not twist – reposition feet instead.  Take care to avoid trip hazards, 

slippery or wet surfaces and when climbing steps and stairs.  Always 

use assistance if required.

Carriage of carton from point of delivery to point of installation – 

roofspace.

Recommend 2-person lift. Ensure co-ordinated movements during lift. 

Avoid upper body/top heavy bending - do not lean forward/sideways.  

Clear the route before attempting the lift.  Take care to avoid trip 

hazards, slippery or wet surfaces and when climbing steps and stairs.  

When transferring appliance into roofspace, recommend 1 person to 

be in roofspace to receive the appliance and other person to be below 

to pass up and support appliance.  Ensure safe lifting techniques are 

used – keep back straight – bend using legs. Keep load as close to 

body as possible.  Always use assistance if required.  It is assumed 

safe access, flooring and adequate lighting are provided in the roof 

space.  It is recommended a risk assessment of the roof space area 

be carried out before moving the appliance into the area to take into 

account access, stability of flooring, lighting and other factors, and 

appropriate measures taken.

Unpacking of appliance from carton.

Recommend 2 persons unpack appliance from carton.  Always keep 

working area clear.  Cut the carton straps, lift carton up and slide over 

polystyrene end packs. Remove top polystyrene pack with fittings.

Positioning of appliance for final Installation – no obstructions.

Recommend 2 persons lift appliance to position into place. Fit bracket 

securely onto wall before lifting appliance into position.  Obtain firm 

grip on front and sides of appliance, lift upwards, ensure stable bal-

ance achieved and lift upwards to position in place on bracket. Ensure 

safe lifting techniques are used – keep back straight – bend using 

legs - when lifting load from floor level.  Do not twist – reposition feet 

instead.  Keep boiler as close as possible to body throughout lift to 

minimise strain on back.  Ensure co-ordinated movements to ensure 

equal spread of weight of load.  Always use assistance if required.  

Recommend wear suitable cut resistant gloves with good grip to 

protect against sharp edges and ensure good grip when handling 

appliance. 

Positioning  of appliance  for  final  Installation  –  above  worktop, 

foreseeable obstructions etc.

Recommend 2 persons lift appliance to position into place. Fit bracket 

securely onto wall before lifting appliance into position.  Obtain firm grip 

on front and sides of appliance, lift upwards, onto worktop if practicable.  

Ensure stable balance achieved and lift upwards to position in place on 

bracket. If 2 persons positioning onto bracket obtain firm grip at front 

and  sides/base  of  boiler.    Ensure  co-ordinated  movements  during  2 

person lifts to ensure equal spread of weight of load. Ensure safe lifting 

techniques are used – keep back straight – bend using legs - when lift-

ing load from floor level.  Do not twist – reposition feet instead.  Keep 

boiler as close as possible to body throughout lift to minimise strain on 

back.  Avoid upper body/top heavy bending - do not lean forward/side-

ways.  Always use assistance if required.  Recommend wear suitable 

cut resistant gloves with good grip to protect against sharp edges and 

ensure good grip when handling appliance.

Positioning of appliance for final Installation – within compart-

ment etc. restricting installation.

Recommend 2 persons lift appliance to position into place, space per-

mitting.  Fit bracket securely onto wall before lifting appliance into po-

sition.  Obtain firm grip on front and sides of appliance, lift upwards, 

onto worktop if practicable.  Ensure stable balance achieved and lift 

upwards to drop into place onto bracket. If 2 persons positioning onto 

bracket obtain firm grip at front and sides/base of boiler.  Ensure co-

ordinated movements during 2 person lifts to ensure equal spread of 

weight of load.  If 1 person positioning onto bracket recommend obtain 

firm grip supporting base of boiler.  Ensure safe lifting techniques are 

used – keep back straight – bend using legs - when lifting load from 

floor level.  Do not twist – reposition feet instead.  Keep boiler as close 

as possible to body throughout lift to minimise strain on back.  Always 

use  assistance  if  required.    Recommend  wear  suitable  cut  resistant 

gloves with good grip to protect against sharp edges and ensure good 

grip when handling appliance. 

Positioning of appliance for final Installation – in roof space re-

stricting installation.

Recommend 2 persons lift appliance to position into place, space per-

mitting.  Fit bracket securely onto wall before lifting appliance into po-

sition.  Obtain firm grip on front and sides of appliance, lift upwards, 

ensure stable balance achieved and lift upwards to drop into place onto 

bracket.  If 2 persons positioning onto bracket obtain firm grip at front 

and  sides/base  of  boiler.    Ensure  co-ordinated  movements  during  2 

person lifts to ensure equal spread of weight of load.  If 1 person po-

sitioning onto bracket recommend obtain firm grip supporting base of 

boiler.  Ensure safe lifting techniques are used - keep back straight – 

bend using legs - when lifting load from floor level. Do not twist – repo-

sition feet instead.  Keep boiler as close as possible to body throughout 

lift to minimise strain on back.  Always use assistance if required.  Rec-

ommend wear suitable cut resistant gloves with good grip to protect 

against sharp edges and ensure good grip when handling appliance.  

It is recommended a risk assessment of the roof space area be car-

ried out before moving the appliance into the area to take into account 

access, stability of flooring, lighting and other factors, and appropriate 

measures taken.

Содержание 12 hxi G.C.No. 41-019-01

Страница 1: ...nstallation and Servicing Condensing Boilers Ultracom hxi 12 hxi G C No 41 019 01 15 hxi G C No 41 019 02 18 hxi G C No 41 019 03 24 hxi G C No 41 019 04 30 hxi G C No 41 019 05 38 hxi G C No 41 019 0...

Страница 2: ...guarantee registration card If your guarantee registration card is missing you can obtain a copy or record your registration by telephoning the Glow worm Customer Service number 01773 828100 Guarantee...

Страница 3: ...Water Condensate Connection 8 20 Electrical Connection 9 22 Commissioning 10 23 Servicing 11 27 Fault Finding 12 31 Replacement of Parts 13 38 Spare Parts 14 43 Manual Handling 15 44 Declaration of Co...

Страница 4: ...Keep load as close to body as possible Always use assistance if required Electrical Supply The boiler MUST be earthed All system components shall be of an approved type and all wiring to current I E E...

Страница 5: ...SHH The Current I E E Wiring Regulations Where no specific instructions are given reference should be made to the relevant British Standard Code of Practice In IE the installation must be carried out...

Страница 6: ...rnal to the house Release an ice blockage by the use of warm cloths on the pipe The boiler should then restart Condensate Drain A plastic drain pipe must be fitted to allow discharge of condensate to...

Страница 7: ...ta 7 13497 SEDBUK rating 2005 90 5 90 6 90 8 SEDBUK rating 2009 88 9 88 7 89 2 C13 C33 C43 C13 C33 C43 C13 C33 C43 C13 C33 C43 C13 C33 C43 C13 C33 C43 SEDBUK rating 2005 90 5 90 5 90 4 SEDBUK rating 2...

Страница 8: ...205 2 Boiler Dimensions Hydraulic Schematic All dimensions are given in millimetres except as noted The general arrangement of the boiler is shown in diagram 2 1 and the hydraulic and gas schematic di...

Страница 9: ...external access is not practicable consideration should be given for the space required to insert the flue internally which may necessitate clearance larger than those specified in diagram 3 1 3 3 Ti...

Страница 10: ...terminal must be exposed to the external air allowing free passage of air across it at all times Being a condensing boiler some pluming may occur from the flue outlet This should be taken into conside...

Страница 11: ...the terminal 300 I above adjacent ground or balcony level 300 J 2 from surface or a boundary facing the terminal 600 Position Position of the flue terminal mm L from opening door window in car port in...

Страница 12: ...t fitted 80 125 mm L 1 Key 1 Gasket fitted Type Max length 60 100 10 m 80 125 25 m Each time an additional 90 bend is necessary or 2 at 45 the length L must be reduced by 1 m 4 2 2 Vertical concentric...

Страница 13: ...e manufacturers instructions supplied The appliance maximum flue length must be included when calculating the overall design of the flue system NOTE The horizontal flue terminal must be removed MODEL...

Страница 14: ...0020107233_00 06 11 Glow worm INSTALLATION 14 12342 Diagram 5 1...

Страница 15: ...m should also be flushed Flushing should be carried out in accordance with BS7593 2006 using a cleanser such as Sentinel X300 or X400 Fernox Restorer or Salamander corrosion guard cleaner IMPORTANT En...

Страница 16: ...ing pump see the diagrammatic layout diagram 5 3 unless laid down differently by the manufacturer The expansion vessel volume depends on the total water system volume and the initial system design pre...

Страница 17: ...CONTROL VALVE TYPE CA BACKFLOW PREVENTION DEVICE BOILER RETURN FLOW BOILER RETURN FLOW Method 1 Diagram 5 4 11680 TEMPORARY CONNECTION HOSE UNION HOSE UNION SUPPLY PIPE CONTROL VALVE CONTROL VALVE DO...

Страница 18: ...tending the dashed inclined line on the template to the side wall This dashed line is drawn at 44mm metre 2 5 rise from the boiler Where this line reaches the side wall a horizontal line should be mar...

Страница 19: ...ue to the varied site conditions we do not supply fixings and advise that the installer should supply those which are suitable 7 2 Boiler Hanging IMPORTANT With regards to the Manual Handling Operatio...

Страница 20: ...ngs DO NOT use adhesive when connecting to the spigot The drain pipe should be non corrosive plastic IMPORTANT Please remove spigot bung before fitting condensate drain connection The condensate drain...

Страница 21: ...0020107233_00 06 11 Glow worm INSTALLATION 21 Diagram 8 3 13000...

Страница 22: ...spur box provided that it is not used in a room containing a fixed bath or shower The boiler is suitable for installation in bathroom zones 2 and 3 9 1 Electrical Wiring Remove the electrical cartrid...

Страница 23: ...e Health and Safety Executive and in accordance with the current issue of BS6798 DO NOT operate the boiler without water Make sure that the system has been thoroughly flushed out with cold water and t...

Страница 24: ...Central heating Boiler functions ALL switched off OFF 3 Turn ON your external controls and select the room temperature required The boiler will operate automatically NOTE The display will indicate th...

Страница 25: ...813 10 9 Instruct the User Demonstrate then instruct the User about the lighting procedure and heating system controls operation Advise that to ensure the continued efficient and safe operation of the...

Страница 26: ...nce does not light goes to lockout F1 turn the throttle anti clockwise a further turn and press the reset button The appliance will after a short delay again attempt to fire Repeat this procedure up t...

Страница 27: ...to touch any internal components proceed as follows Connect the CO2 combustion analyser to the relevant test point see diagram 11 1 Diagram 11 1 15442 G31 BURNER CO2 MODEL CHECK case on SETTING case...

Страница 28: ...ted this will force the boiler to minimum rate and the display will flash Lo indicating the boiler is operating at minimum Wait until the CO2 value is stable and check that the value is within the ran...

Страница 29: ...ctrode carefully from the combustion chamber see diagram 11 4 Inspect the tips for damage Clean away any debris and check the spark gap is 3 5 to 4 5 mm Check the electrode gasket for signs of damage...

Страница 30: ...the heat exchanger any remaining debris should pass through the condensate trap Ensure the water is kept away from electrical components 11 5 Inner Casing Panel Seal check Check the condition of the s...

Страница 31: ...10 5 Check that the heating system pressure indicates at least 1mb if not fill and vent the system as described in section 10 2 Check that all external controls are on Check the functional flow diagr...

Страница 32: ...0020107233_00 06 11 Glow worm MAINTENANCE 32 Diagram 12 4 13456...

Страница 33: ...0020107233_00 06 11 Glow worm MAINTENANCE 33 13012 Diagram 12 5 CENTRAL HEATING...

Страница 34: ...0020107233_00 06 11 Glow worm MAINTENANCE 34 13508 Diagram 12 6 Fault Codes...

Страница 35: ...ttons to scroll to 96 This is the installer level access password c Press MODE to confirm see diagnostic display 1 Use the or buttons to view the appropriate diagnostic number see diagram 12 7 If nece...

Страница 36: ...n Relay 1 Reserved for future use d 91 Internal Programmer type 0 24 hour default 1 7 day d 92 Enable Disable Internal Programmer 0 CH Off DHW Off default 1 CH Off DHW On 2 CH On DHW Off 3 CH On DHW O...

Страница 37: ...0020107233_00 06 11 Glow worm MAINTENANCE 37 Diagram 12 8 13568 STATE LISTS State list Accessed through Diagnostic Codes Level 1 Installer Access d 99...

Страница 38: ...the front of the inner front panel and lift off The side panels can be hinged sideways and removed to aid replacement of parts To hinge a side panel undo and remove the three screws securing each sid...

Страница 39: ...fan gas valve and burner assembly Remove the four screws that secure the burner see diagram 11 6 NOTE The burner will require a new gasket when refitted 13 8 Front Insulation For access refer to secti...

Страница 40: ...ve the float to clean it Remove any solids found Flush water through the trap to remove any remaining solids Check for any debris in the outlet hose of the condensate drain and clean as necessary 13 1...

Страница 41: ...Remove the electrical connections from the thermistor Remove the retaining clip from the flow pipe NOTE When reconnecting the polarity of the wiring to thermistors is not important 13 15 Heating Retur...

Страница 42: ...Remove electrical connection Gently ease back the retaining clips see diagram 13 13 Withdraw the board 13 19 Fuse Main PCB Control Box For access refer to section 13 16 The fuse is located at top lef...

Страница 43: ...ring from British Gas also quote the G C number of the part Key No Part No Description GC Part No 1 2000802463 Burner 12 15 18hxi E84021 1 2000802662 Burner 24 30 38hxi H36356 2 801655 Igniter E84015...

Страница 44: ...ton up and slide over polystyrene end packs Remove top polystyrene pack with fittings Positioning of Appliance for Final Installation no obstructions Recommend 2 persons lift appliance to position int...

Страница 45: ...0020107233_00 06 11 Glow worm MAINTENANCE 45...

Страница 46: ...a...

Страница 47: ...Number Comments Signature SERVICE 7 Date Energy Ef ciency Checklist completed Yes No Engineer Name Company Name Telephone Number Engineer ID Number Comments Signature SERVICE 9 Date Energy Ef ciency...

Страница 48: ...Belper Derbyshire DE56 1JT Because of our constant endeavour for improvement details may vary slightly from those shown in these instructions www glow worm co uk Subject to engineering changes 002010...

Отзывы: