206M 201805
32
imbalance optimize
Imbalance optimize have two operation method:
8.1 Already display balance value
If already finish balance testing, when you need process imbalance optimize, press OPT
key, display Fig 8-1;
Fig 8-1
Use chalk mark a reference point on the flange and rim and tyre, use tyre changer to exchange
rim and tyre by 180°
Re-install wheel on the balancer and make sure mark of reference point between the flange
and rim must be on the same position. Quickly rotate wheel to balance wheel, after rotation stop,
display Fig 8-2;
Fig 8-2
As per above Fig 8-2, left display shows percent of optimize. If before optimize static value is
40 gram, optimized percent is 85%, so after optimize static value only 6 gram remain
(15%×40gram=6gram);
Slowly rotate wheel by hand, when both end sides two of position indicator light flash (Fig 8-3)
,
use chalk to make a mark on the tyre
Fig 8-3
Slowly rotate wheel by hand again, when both side middle position indicator light flash ( Fig
8-4)
,
use chalk to make a mark on the rim
Fig 8-4
Demount wheel from balancer, use tyre changer to demount tyre from rim. Remount tyre on rim
to make tyre and rim marks at same position. Optimize complete.
8.2 After power on and before balancing, also may process imbalance optimize directly
Turn on the power, install wheel, press OPT key, left side display shows OPT, quickly rotate
wheel for balance testing. When rotation stops, display shows Fig 8-1, follow 8.1 operation. Press
[SET] key to stop operation
9. Self-calibrating of Dynamic Balancer
The self-calibrating of dynamic balancer was finished before ex-factory, but the system