206M 201805
30
enter ALU-3 mode to balance wheel
Input rim data, manually rotate wheel, when display shows “RUN ---”, move hand away
to let wheel rotate. When display shows “STOP”, wheel stops and display shows data. Slowly
rotate wheel, when inside position indication LEDs all light,
(
Fig 5-1
(
10
)
)
, at the 12 o’clock
position of rim inside edge , clamp weights equal to value shown on the left side display
(
Fig
7-9 left
)
。
Then slowly rotate wheel, when outside position indication LEDs all light,
(
Fig 5-1
(
11
)
)
, at the 12 o’clock position of rim inside , stick weights equal to value shown on the right
side display
(
Fig 7-9 right
)
. Rotate wheel by hand again, when display shows “RUN ---”,
move hand away to let wheel rotate. When both side display are on, wheel stops and
balancing is completed
Fig 7-9
7.7 ALU-S mode data input method and balancing operation
Above three ALU modes may not be suitable for all structure rims. Balancing
performance is not good under above three ALU modes for some rims. Then ALU-S mode can
be adopted. Input rim data method as follows:
Press [MODE] key, to make ALU-S mode indication light on. Mode indication as
following figure :
As per Fig 7-8 or Fig 7-9, move scale to rim inside (aI position ), measure rim inner
distance (aI) value, press [a-] or [a+] to input aI value
Move scale further inside to aE position, measure distance aE value, press [b-] or [b+]to
input aE value
Measure rim diameter at aI position, press [d-] or [d+] to input dI value
Measure rim diameter at aE position, press [FINE] and [d-] or [d+] to input dE value
Fig 7-8