USER MANUAL
Range BEAT-Tr
Edition: January 2016
Revision: No. 3
MODE OF USE -
25
Reading the fitting’s barcode using
scanner.
Read the fitting’s barcode with the scanner
connected to the serial connector.
WARNING !
Make sure you always read the
barcode corresponding to the
fitting to be electrofused. Should
you not record the fitting’s data,
this could cause errors in the
electrofusion process that would
have repercussions on the quality
and reliability of the joint.
If the barcode or reading were incorrect.
FUSION DATA:
WRONG DATA
Error mes-
sage.
Two acoustic signals are emitted and it returns
to the start.
When the data have been satisfactorily cap-
tured, the screen will show the following mes-
sage:
FUSION DATA: I AG
d20 40,0V 34s
I n f o r m a t i o n
captured.
Where it involves a (I) Agru coupler of diame-
ter 20, 40 Volt and 34 seconds (nominal).
L
Entering joint data without barcode: via
the keyboard.
Click one of the 4 arrows. The display will show
the following screen:
FUSION DATA: 23ºC
VOLTAGE(Volt):
$
40.0
40.0 Volt
by default.
The electrofusion voltage should be be-
tween 8 and 48 V.
Enter voltage. Press the
¨
and
§
arrows to
move the cursor to a different field and the
©
and
ª
arrows to select the values.
Press START/VALIDATE to pass to the next
screen.
FUSION DATA: 23ºC
TIME(s):
$
000
“0000" by
default.
Maximum permitted time of 5940 seconds
(99 minutes).
Enter the time indicated by the fitting manu-
facturer, bearing in mind the correction given
according to the ambient temperature (accord-
ing to the manufacturer). Press the
¨
and
§
arrows to move the cursor to a different field
and the
©
and
ª
arrows to select the values.
Main symbols used (for the full list, please see ISO/TR 13950):
I
Monofilar coupler
Y
Reducer
.t.
Saddle
T
Tee
[
Single socket
C
Elbow