- TROUBLESHOOTING
Revision: No. 3
44
4.2.2 Fitting resistance outside margins:
ERR1 Once the electrofusion process has begun and where data is captured exclusively
by barcodes, if the fitting resistance is higher than the tolerances established by
the fitting’s manufacturer, the display will show:
FAILURE OF FITTING
RESISTENCE TOO HIGH
If this message persists, send the unit the After-Sales Service to check the
calibration of the resistance measure.
ERR8 Once the electrofusion process has begun and where data is captured exclusively
by barcodes, if the fitting resistance is lower than the tolerances established by the
fitting’s manufacturer, the display will show:
FAILURE OF FITTING
RESISTENCE TOO LOW
If this message persists and after checking that fitting and barcode resistance are
correct, send the unit the After-Sales Service to check the calibration of the
resistance measure.
4.2.3 Interruption by operator:
ERR7 If the operator presses the <STOP> key once the electrofusion process has begun,
the display will show:
<STOP> PUSHED
xxxxs
Where xxxxs corresponds to the remaining
cycle time at the moment of stopping.
4.2.4 Output current:
ERR3 If the electrofusion current is excessive, the display will show:
CURRENT TOO HIGH
xxxxs
Where xxxxs corresponds to the remaining
cycle time at the moment of stopping.
This message appears in the following cases:
1. When the connected fitting has a very low resistance, outside the margins.
2. Crossed fitting resistance.
ERR4 If the electrofusion current is very low, the display will show:
CURRENT TOO LOW xxxxs
Where xxxxs corresponds to the remaining
cycle time at the moment of stopping.