INS T ALLAT I ON   M A N U A L

 
Follow the procedure described below:

Ø  

Disconnect the pipes from the gas control (flexible gas pipe, aluminium pilot burner pipe and thermocouple 1);
 

!Caution

The red wire of thermocouple 2, if applicable, must remain connected to the gas control.
 

Ø

Disconnect the gas control from the burner mounting plate by unscrewing the self-tapping screw.

Ø

Carefully unwind the red and black wire of thermocouple 2, if applicable.

Ø

Carefully lay the gas control together with the wires of thermocouple 2, the ignition cable, the flexible gas hose, 
the aluminium pilot burner pipe and the type plate plus chain in the direction of the control hatch.
 

!Caution

Prevent dirt in gas pipes and connections;

Avoid kinks in the pipes.

!Caution

Make sure the ignition cable cannot come into contact with other wires;

The data plate should remain attached to the chain.

 

Ø

Set the height of the appliance using the adjustable feet (if applicable).

Ø

Make the appliance level at the same time.
 

!Tip

The construction frame for most 2 or 3 sided appliances can be adjusted. This will allow you to connect the 
construction frame to the chimney breast correctly. For 2 or 3 sided appliances that cannot be adjusted, we would 
like to refer you to chapter 5.9 'Additional instructions'.

!Caution  

do not ignite the appliance before the gas and discharge connections have been fully installed, first observe the 
procedure described in chapter 7.3.
 

5.5 Placing the chimney breast

 (if applicable)

In order to provide proper heat discharge, there should be sufficient space around the appliance. The chimney 
breast should be ventilated sufficiently by means of ventilation holes (incoming and outgoing).
 

!Caution

Use non combustible and heat-resistant material for the chimney breast, including the top of the chimney 
breast, the material inside the chimney breast and the back wall of the chimney breast.

Make sure that the appliance is not carrying the weight of the chimney breast when using stone-like 
materials.

The passage of the ventilation holes (outgoing), which are placed as high as possible, is stated in Appendix 2, 
Table 2.

!Caution

When placing the chimney breast, you should take the following into account (see Appendix 3, fig. 2):

the location of the control hatch: this must be placed as low as possible;

the dimensions of the control hatch; see Placing the control hatch section 5.6;

the Dru control hatch is not supplied with all appliances. Nevertheless, we recommend only using a Dru 
control hatch, if available, exept in the case of B

11 AS/BS

 appliances. If you decide not to take this option, you 

will have to make a 100 cm

2

 ventilation hole that is placed as low as possible, for the benefit of the incoming 

ventilation;

the location of the ventilation holes (V) (outgoing);

maintain a minimum 30 cm distance between the top of the ventilation hole (outgoing) and the ceiling of the 
house.  

the measurements of the glass pane, so that it can be placed/removed after placing the chimney breast;

the protection of the gas control and the pipes against cement and plaster.

If possible, you should place decorative strips, frames, etc., after any required structural work has been 
completed. Avoid the use of painter's tape. If this is not possible: please use good quality painter's tape and 
remove it immediately after plastering or painting work has been completed.

!Tip

You should preferably apply the ventilation holes (outgoing) on both sides of the chimney breast. You can use 
DRU ventilation elements.

Prior to completely closing the chimney breast, check whether the discharge / concentric system is placed 
correctly.

whether the channels, fixing brackets and possible clip bindings, which cannot be reached after installation, 
are fastened by means of self-tapping screws.

7

Содержание 70XT BF

Страница 1: ...l i s h Store this document in a safe place Global 70XT BF 01 RCE Installation manual DRU 823266 EN US 0721 4 G20 G25 G25 3 Natural gas G31 Propane EN 959 118 01 EN Scan this QR Code for DRU Video As...

Страница 2: ...neral 5 8 2 Construction of the concentric system 5 8 3 Placing the concentric system 5 8 4 Connection existing chimney 5 9 Additional instructions 5 10 Glass pane 5 10 1 Removing the glass pane 5 10...

Страница 3: ...tely prior to installing this appliance If you use the DRU Powervent system or the DRU Smartvent system you must carefully and fully read and use the accompanying installation manual as well prior to...

Страница 4: ...re there is sufficient ventilation of the room where the appliance is installed according to legislation If you are installing an appliance with a closed combustion only use the concentric systems sup...

Страница 5: ...iance Check the appliance and accessories for damages during transport If necessary contact your supplier Never install an appliance that is damaged Remove any screws that are used to fix the applianc...

Страница 6: ...nket or any other material Make sure that the appliance to be installed has a stable position Attach the appliance if applicable to the wall using the wall brackets and or fasten the extending legs wi...

Страница 7: ...top of the chimney breast the material inside the chimney breast and the back wall of the chimney breast Make sure that the appliance is not carrying the weight of the chimney breast when using stone...

Страница 8: ...from dirt Reconnect the pipes to the gas control Caution Avoid kinks in the pipes Tighten the flexible gas pipe and the pilot burner pipe until they are gastight First tighten the thermocouple by hand...

Страница 9: ...wise Maintain a distance of at least 50 mm between the outside of the concentric system and the walls and or ceiling If the system is built in for instance a cove it should be made with non combustibl...

Страница 10: ...terminal the following applies The construction of the chosen system when using a roof terminal must be permissible according to Appendix 2 Table 5 See the method of working described below The worki...

Страница 11: ...the wall terminal from the outside by means of four screws Determine the remaining length for the wall or roof terminal and cut it to size make sure the correct insertion length is maintained Place th...

Страница 12: ...the 4 self tapping screws for the lower pane clamping strip C from the frame and remove the lower pane clamping strip Unscrew the middle 2 self tapping screws from the frame and remove the upper pane...

Страница 13: ...d point to the rear Adjust the position of the restrictor slide R using situations B to C in appendix 2 table 6 The letter of the position on the restrictor slide corresponds with the letter of the si...

Страница 14: ...g the vermiculite Caution The vermiculite should not get higher than the edge of the burner The burner deck has to remain covered with vermiculite in order to prevent reduction of the burner s life sp...

Страница 15: ...in order to avoid damaging the receiver Avoid formation of dust on or in the receiver cover it when performing work Place the receiver in its intended holder under the appliance or in the control hat...

Страница 16: ...ow position ignition and switching off Tip If the external control system has an intelligent clock function and or thermostat function the remote control supplied with the appliance should have the ma...

Страница 17: ...ches off after 22 seconds This happens because the appliance is equipped with a second thermocouple and the glass window has not been placed In this case you may presume that the main burner will cont...

Страница 18: ...he system as a result of pitting corrosion If required clean the following components the pilot burner malfunction search diagram Appendix 1 the space surrounding the pilot burner the glass pane s Cau...

Страница 19: ...door openers Instruct the user about the appliance and the remote control When the appliance is started for the first time point out that In order to avoid cracks in a chimney breast made of stone lik...

Страница 20: ...bend tip 1 mm higher Spark too weak thin and reddish Act as if no spark in box 2 05 and perform actions described for ignition cable and ignition electrode Pilot flame too weak dirty Remove injector r...

Страница 21: ...venly distributed across burner s chips on burner lack of combustion air See 2 15 cross lighting in low setting possible when thermostat function is used 2 15 Check Gas supply Supply pressure does not...

Страница 22: ...and brief noise of servomotor to confirm that communication code was set succesfully Remote control Battery 9V empty see indication on display Several After switching off going out the remote set is l...

Страница 23: ...ir inlet guide Key bolts M8x 140x50 Hexagonal nut M8 Washer M8 Spare self tapping screws for mounting the glass panes Socket spanner 8 mm Remote control with receiver 9V block battery Penlite battery...

Страница 24: ...0 65 2x 0 85 1 35 1 92 4 89 1 92 4 A Unit kW kW mg kWhinput GCV kW kW kW kW L h L h mbar mbar mm mm kW kW kW kW Type of heat output room temperature control Single stage heat output no room temperatu...

Страница 25: ...of meters vertical pipe length 0 8 4 0 51 0 8 Total number of meters horizontal pipe length excluding wall terminal 0 3 0 Table 4 Conditions for setting the appliance See Figure 4a 4b Air inlet guide...

Страница 26: ...l i s h INSTALLATION MANUAL 26 Table 5 Determining permissibility concentric system with roof terminal G20 G25 G25 3 Total number of meters horiz pipe length Total no of meters vertical and or sloping...

Страница 27: ...permissibility concentric system with roof terminal G31 Total number of meters horiz pipe length Total no of meters vertical and or sloping pipe length no bends 2 bends 3 bends 4 bends 5 bends Situat...

Страница 28: ...E n g l i s h INSTALLATION MANUAL Appendix 3 Figures 28 min 939 max 959 50 600 720 757 815 100 150 A A min 179 max 199 621 18 340 130 38C 2575 0 1...

Страница 29: ...g l i s h INSTALLATION MANUAL 29 min 15 max 100 min 342 761 min 177 625 min 560 B A C 38c 2576 0 250 700 C 2 2 B 2 2 A max 690 max 690 815 min 230 min 93 min 230 VOUT Tot min 200cm 2 VIN Tot min 80cm...

Страница 30: ...E n g l i s h INSTALLATION MANUAL 30 A B D C E 2x 38C 2587 0 1 2 3 4 5 1 2 6 4 3 5 38c 1078 3 0 3m 0 8 4m 38C 744ZJ 1x90 0 5 0 8m 0 m 38C 744ZZ 1x90 5 3 4a 4b...

Страница 31: ...E n g l i s h INSTALLATION MANUAL 31 U T S 38c 2577 0 R L G H M 38c 2578 0 7 6...

Страница 32: ...E n g l i s h INSTALLATION MANUAL 32 38P 0804 0 38P 0805 0 38p 0022 38P 0608 38P 0028 1 12 8 9 10 11...

Страница 33: ...E n g l i s h INSTALLATION MANUAL 33 38P 0806 0 A B C D E F G H A B 38P 0807 0 C 14 13...

Страница 34: ...E n g l i s h INSTALLATION MANUAL 34 38P 0808 0 F D 38P 0809 0 E 16 15...

Страница 35: ...E n g l i s h INSTALLATION MANUAL 35 H 38P 0810 0 G B V A S N 38p 0180 38p 0179 38p 0181 38 36 39 40 41...

Страница 36: ...E n g l i s h INSTALLATION MANUAL 36 38C 1940 5mV 38p 0182 122 A A 18 16 SECTION A A SCALE 1 3 38c 2579 0 44 42 43...

Страница 37: ...E n g l i s h INSTALLATION MANUAL 37...

Страница 38: ...E n g l i s h INSTALLATION MANUAL 38...

Страница 39: ...E n g l i s h INSTALLATION MANUAL 39...

Страница 40: ...E n g l i s h DRU Verwarming B V The Netherlands Postbus 1021 NL 6920 BA Duiven Ratio 8 NL 6921 RW Duiven EN...

Отзывы: