 IN ST AL LA TI ON  M AN U AL 

yes

Start

2.01 Can pilot be lit?

2.03 Only one spark?

2.02 Sparking?

2.09 

Ignition procedure

-  Oval knob on gas control is on 

"MAN". Set to "ON" and restart.

 

Retarded ignition of main 
burner(s)

Gas to main burner opens ca. 3-5 
seconds after servo motor, 
operating the gas valve, starts 
running (sound of motor!). After 
this the main burner is to ignite (at 
least partially) within 10 seconds 
and not with a firm noise WHOOF. 
If not: no or delayed cross lighting 
of main burner.

Hazardous situation.

Stop ignition procedure straight 
away and first check for:
-  Position of logs or pebbles.
-  Burner holes (locally) blocked.

Remove vermiculite dust.

-  Vermiculite missing.
-  Chips on burner.
-  Vermiculite not distributed 

evenly across burner(s).

 

PowerVent® (if present)

Burner does not light. Consult 
PowerVent® installation manual 
how to carry out the checks below.
Check:
-  230 V to fan controller unit and 

fan.

-  Silicon pressure measurement 

hoses:
- swapped;
- leaking or barred.

-  Pressure difference set too high.
-  Resistance of flue system too 

high:
- adjustment (of appliance 
damper and air inlet guides);
- flue length or number of bends 
too large;
- dirty (e.g. cobwebs).

-  Operation of the fan.
-  Operation of solenoid gas valve.
-  Operation of fan controller unit.
-  Operation of pressure 

measurement gauge.

2.11 

No proper cross lighting 

of main burner(s).

Go to box 2.09 and take 
actions act as described for 
'retarded ignition of main 
burner'.                          

2.06 Pilot can be lit.
Does it stay alight? 

2.10 Do(es) main burner(s) 
ignite smoothly and across 
its/their full length after first 
ignition by pilot burner? 

2.08 Does main burner 
ignite immediately?

2.04 Check:

Receiver

-  Replace missing, weak or 

rechargeable batteries (not enough 
power to open thermoelectric 
valve).

 

Presence of gas on pilot burner

Check pilot on presence of gas at 
normal ignition cycle or in Manual 
Mode (turn oval knob on gas control 
to MAN and keep safety shut off 
valve opened with a screwdriver) and 
ignite pilot with a lighter.
-  Pilot flame not on: Step 1.
-  Pilot flame on: Step 2.
 

Step 1: Pilot has no gas

Check:
-  Gas tap open?
-  Gas at gas control (line pressure at 

measuring point on gas control).

-  Gas flowing out of gas control? (by 

loosening pilot tube at gas control).
If not: check adjustment screw pilot 
flame (under black cover): sealing 
not to be broken.
Sealing broken: screw should be 
fully open.

-  Blocking of pilot tube (kink or dirt).
-  If this does not help: replace gas 

control.

                       

Step 2: Pilot has gas, but no 
ignition

-  Electrode with 

90° bended

 tip: 

bend tip 1 mm higher.

-  Spark too weak (thin and reddish).

Act as if 'no spark' in box 2.05 and 
perform actions described for 
ignition cable and ignition 
electrode.

-  Pilot flame too weak (dirty). 

Remove injector (remove gland nut 
and the pilot tube). See that it does 
not fall away. Clean with 
compressed air.

Rectify. Retry. 

2.05 Check:

Ignition cable

-  Present and connected.
-  Being free from metal parts or 

concrete.

-  Too long: cut away all excessive 

length at receiver end, and 
reconnect.

-  Shorting out to earth: replace 

ignition cable.

-  Spark in wrong position:

- slide rubber sleeve on ignition 
cable over ceramic of electrode.

-  Replace electrode if neccessary.
 

Ignition electrode

-  

Straight

 electrode:

- oxidation (roughen electrode 
with file or sand paper);
- position (4 mm from pilot burner).

-  Cracks in ceramic (not always 

visible): replace electrode.

 

Starting procedure

After switching off/going out the 
remote is locked for 120 sec. (older 
versions 60 sec).
Wait 2 minutes before reigniting.

2.07

Pilot out when servomotor starts 
to run? Check the thermocouple 
system.

-  Measure thermocouple voltage in 

mV just after servomotor starts to 
run and the voltage goes down.

-  Measure between red dot on 

receiver and earth point on gas 
control (fig. 42).
- 0 mV
- 2-3 mV
- 3-5 mV
- 6 mV and higher

-  Requirement: after rectification 

actions thermocouple voltage 
should be 6 mV at least, just after 
motor starts running!

Voltage 0 mV

-  Thermocouple defective. Check by 

replacing or measuring voltage at 
end whilst heating (tip: with a 
lighter).

-  Short circuiting or interruptions in 

circuit:
Check:
- thermocouple tight in 
interruptor;
- interruptor tight in gas control;
- black wires (yellow/red end) 
connected to inter 
receiver;
- interruptor (mount 
thermocouple directly in gas 
control and ignite in Manual Mode 
(see 2.04).
If pilot stays on: interruptor 
defective.

Voltage 2-3 mV

-  Check pilot flame.

Too small:
- pilot dirty.
Clean up (see 2.04).
- check  for pilot gas tube 
tightness;
- pilot tube kinks or dirt inside;
- line pressure too low.

-  Tip: thermo couple not in (correct!) 

pilot flame.
Bend into flame.

Voltage 3-5 mV

-  Appliance may work, but is too 

critical.
Perform actions as described for 
2-3 mV.

Voltage 6 mV and higher

Voltage OK, so different cause.
-  Receiver defective. Check by 

dismounting black-red and yellow 
control cables from receiver and 
link together. Ignite fire in Manual 
Mode (see 2.04). Pilot stays on: 
receiver defective.

-  Gas control defective if receiver is 

not defective. Replace gas control.

yes

no

yes

yes

no

no

no

no

no

Fires with electronic ignition, fault finding: Ignition and burning

Appendix 1 diagnosis of malfunctions  

GB

20

2.03a
-  Loosen and retighten 

earthing screw on gas 
control.

-  If this does not work: 

replace receiver.

yes

yes

Содержание 70XT BF

Страница 1: ...l i s h Store this document in a safe place Global 70XT BF 01 RCE Installation manual DRU 823266 EN US 0721 4 G20 G25 G25 3 Natural gas G31 Propane EN 959 118 01 EN Scan this QR Code for DRU Video As...

Страница 2: ...neral 5 8 2 Construction of the concentric system 5 8 3 Placing the concentric system 5 8 4 Connection existing chimney 5 9 Additional instructions 5 10 Glass pane 5 10 1 Removing the glass pane 5 10...

Страница 3: ...tely prior to installing this appliance If you use the DRU Powervent system or the DRU Smartvent system you must carefully and fully read and use the accompanying installation manual as well prior to...

Страница 4: ...re there is sufficient ventilation of the room where the appliance is installed according to legislation If you are installing an appliance with a closed combustion only use the concentric systems sup...

Страница 5: ...iance Check the appliance and accessories for damages during transport If necessary contact your supplier Never install an appliance that is damaged Remove any screws that are used to fix the applianc...

Страница 6: ...nket or any other material Make sure that the appliance to be installed has a stable position Attach the appliance if applicable to the wall using the wall brackets and or fasten the extending legs wi...

Страница 7: ...top of the chimney breast the material inside the chimney breast and the back wall of the chimney breast Make sure that the appliance is not carrying the weight of the chimney breast when using stone...

Страница 8: ...from dirt Reconnect the pipes to the gas control Caution Avoid kinks in the pipes Tighten the flexible gas pipe and the pilot burner pipe until they are gastight First tighten the thermocouple by hand...

Страница 9: ...wise Maintain a distance of at least 50 mm between the outside of the concentric system and the walls and or ceiling If the system is built in for instance a cove it should be made with non combustibl...

Страница 10: ...terminal the following applies The construction of the chosen system when using a roof terminal must be permissible according to Appendix 2 Table 5 See the method of working described below The worki...

Страница 11: ...the wall terminal from the outside by means of four screws Determine the remaining length for the wall or roof terminal and cut it to size make sure the correct insertion length is maintained Place th...

Страница 12: ...the 4 self tapping screws for the lower pane clamping strip C from the frame and remove the lower pane clamping strip Unscrew the middle 2 self tapping screws from the frame and remove the upper pane...

Страница 13: ...d point to the rear Adjust the position of the restrictor slide R using situations B to C in appendix 2 table 6 The letter of the position on the restrictor slide corresponds with the letter of the si...

Страница 14: ...g the vermiculite Caution The vermiculite should not get higher than the edge of the burner The burner deck has to remain covered with vermiculite in order to prevent reduction of the burner s life sp...

Страница 15: ...in order to avoid damaging the receiver Avoid formation of dust on or in the receiver cover it when performing work Place the receiver in its intended holder under the appliance or in the control hat...

Страница 16: ...ow position ignition and switching off Tip If the external control system has an intelligent clock function and or thermostat function the remote control supplied with the appliance should have the ma...

Страница 17: ...ches off after 22 seconds This happens because the appliance is equipped with a second thermocouple and the glass window has not been placed In this case you may presume that the main burner will cont...

Страница 18: ...he system as a result of pitting corrosion If required clean the following components the pilot burner malfunction search diagram Appendix 1 the space surrounding the pilot burner the glass pane s Cau...

Страница 19: ...door openers Instruct the user about the appliance and the remote control When the appliance is started for the first time point out that In order to avoid cracks in a chimney breast made of stone lik...

Страница 20: ...bend tip 1 mm higher Spark too weak thin and reddish Act as if no spark in box 2 05 and perform actions described for ignition cable and ignition electrode Pilot flame too weak dirty Remove injector r...

Страница 21: ...venly distributed across burner s chips on burner lack of combustion air See 2 15 cross lighting in low setting possible when thermostat function is used 2 15 Check Gas supply Supply pressure does not...

Страница 22: ...and brief noise of servomotor to confirm that communication code was set succesfully Remote control Battery 9V empty see indication on display Several After switching off going out the remote set is l...

Страница 23: ...ir inlet guide Key bolts M8x 140x50 Hexagonal nut M8 Washer M8 Spare self tapping screws for mounting the glass panes Socket spanner 8 mm Remote control with receiver 9V block battery Penlite battery...

Страница 24: ...0 65 2x 0 85 1 35 1 92 4 89 1 92 4 A Unit kW kW mg kWhinput GCV kW kW kW kW L h L h mbar mbar mm mm kW kW kW kW Type of heat output room temperature control Single stage heat output no room temperatu...

Страница 25: ...of meters vertical pipe length 0 8 4 0 51 0 8 Total number of meters horizontal pipe length excluding wall terminal 0 3 0 Table 4 Conditions for setting the appliance See Figure 4a 4b Air inlet guide...

Страница 26: ...l i s h INSTALLATION MANUAL 26 Table 5 Determining permissibility concentric system with roof terminal G20 G25 G25 3 Total number of meters horiz pipe length Total no of meters vertical and or sloping...

Страница 27: ...permissibility concentric system with roof terminal G31 Total number of meters horiz pipe length Total no of meters vertical and or sloping pipe length no bends 2 bends 3 bends 4 bends 5 bends Situat...

Страница 28: ...E n g l i s h INSTALLATION MANUAL Appendix 3 Figures 28 min 939 max 959 50 600 720 757 815 100 150 A A min 179 max 199 621 18 340 130 38C 2575 0 1...

Страница 29: ...g l i s h INSTALLATION MANUAL 29 min 15 max 100 min 342 761 min 177 625 min 560 B A C 38c 2576 0 250 700 C 2 2 B 2 2 A max 690 max 690 815 min 230 min 93 min 230 VOUT Tot min 200cm 2 VIN Tot min 80cm...

Страница 30: ...E n g l i s h INSTALLATION MANUAL 30 A B D C E 2x 38C 2587 0 1 2 3 4 5 1 2 6 4 3 5 38c 1078 3 0 3m 0 8 4m 38C 744ZJ 1x90 0 5 0 8m 0 m 38C 744ZZ 1x90 5 3 4a 4b...

Страница 31: ...E n g l i s h INSTALLATION MANUAL 31 U T S 38c 2577 0 R L G H M 38c 2578 0 7 6...

Страница 32: ...E n g l i s h INSTALLATION MANUAL 32 38P 0804 0 38P 0805 0 38p 0022 38P 0608 38P 0028 1 12 8 9 10 11...

Страница 33: ...E n g l i s h INSTALLATION MANUAL 33 38P 0806 0 A B C D E F G H A B 38P 0807 0 C 14 13...

Страница 34: ...E n g l i s h INSTALLATION MANUAL 34 38P 0808 0 F D 38P 0809 0 E 16 15...

Страница 35: ...E n g l i s h INSTALLATION MANUAL 35 H 38P 0810 0 G B V A S N 38p 0180 38p 0179 38p 0181 38 36 39 40 41...

Страница 36: ...E n g l i s h INSTALLATION MANUAL 36 38C 1940 5mV 38p 0182 122 A A 18 16 SECTION A A SCALE 1 3 38c 2579 0 44 42 43...

Страница 37: ...E n g l i s h INSTALLATION MANUAL 37...

Страница 38: ...E n g l i s h INSTALLATION MANUAL 38...

Страница 39: ...E n g l i s h INSTALLATION MANUAL 39...

Страница 40: ...E n g l i s h DRU Verwarming B V The Netherlands Postbus 1021 NL 6920 BA Duiven Ratio 8 NL 6921 RW Duiven EN...

Отзывы: