Pump & Pipe 
Installation Instructions

INSTALLATION D:
CONNECTION  TO  EXISTING  DISCHARGE  PIPE
FOR NARROW SUMP PITS
(Diagram D)

Depending on your installation requirements, PVC
pipe lengths will vary.  Cut the pipes and assemble
them as shown in photo #8.  

Do not cement them

together  until  you  are  sure  they  are  cut  to  the
correct  lengths.

It  is  important  to  keep  the

discharge  pipes  on  both  pumps  parallel  to  each
other, so that the pumps remain flat on the floor
of the sump.  More detailed instructions follow.

Unplug the main AC pump when installing the
backup pump to avoid electric shock.  Failure
to do so could cause serious injury or death.

1. Attach an “L” bracket to the discharge pipe of

the main AC pump with two (2) stainless steel
hose  clamps.    Position  the  bracket  so  the
bottom of the “L” is just above the top of the
main pump, and out of the way of any float
switch on the main pump.

2. (a) Remove the black bottom strainer of the

pump  by  pressing  in  the  two  tabs  on  the
strainer  and  pushing  down.    There  are  holes
suitable  for  mounting  on  the  bottom  of  the
strainer.  (b) Using the #8-32 x ¾” stainless
screw, washer and nut, attach the strainer to
the  “L”  bracket.    (c)  Once  the  strainer  is
attached,  simply  press  the  rest  of  the  pump
onto the mounted strainer.

3. Secure the pump wire so that the plug on the

end  will  not  fall  into  the  sump.    Attach  the
wire to the pipe with a piece of tape.

4. Cut a piece of 1½” rigid PVC pipe long enough

to reach from the elbow of the backup pump
to  one  (1)  foot  above  the  floor.    Prime  and
cement it to the 1½” pipe adapter, then screw
the adapter into the pump.

5. Install  a  check  valve  on  the  top  of  the  PVC

pipe attached to the Pro Series pump.  Make
sure it is installed with the arrow pointing up
or it will not prevent the backflow of water.

6.

When  a  check  valve  is  used,  a  1/8”  hole
must be drilled in the PVC pipe above the
Pro Series pump.  Make sure it is above the
water line and below the check valve.  Drill
the hole at a 45º angle toward the bottom
of  the  sump  to  avoid  splashing  water
outside the sump pit.  If a 1/8” hole is not
drilled  above  the  pump,  an  air  lock  may
prevent the pump from operating.

7. If  there  is  no  check  valve  on  the  discharge

pipe  of  the  main  AC  pump,  one  must  be
installed at this time.  Cut the discharge pipe
approximately  one  (1)  foot  above  the  floor.
Install a check valve on the pipe and tighten
the  bottom  hose  clamp.    Now  prime  and
cement a small piece of 1½” PVC pipe to the
bottom of a “Y” connector.  Prime and cement

the top of the “Y” assembly to the discharge
pipe  with  the  “Y”  extension  facing  down
toward  the  backup  pump.    Now  connect  the
bottom  of  the  assembly  to  the  check  valve
and tighten the hose clamp.

8. Connect  a  piece  of  1½”  PVC  pipe  above  the

check  valve  of  the  Pro  Series  pump,  and
attach  a  45°  elbow  to  that  pipe.    Extend
another piece of pipe to reach from the 45°
elbow to the “Y” connector on the other pipe.

9. Prime  and  cement  all  pipe  connections

securely  to  prevent  leaking,  and  tighten  all
the hose clamps.

!

DANGER

PUMP WIRE

HOSE CLAMPS

PIPE ADAPTER

"L" BRACKET

FLOOR

JOIST

MAIN
AC PUMP 

RIGID

1-1/2"

PVC PIPE

CHECK
VALVE

RIGID

1-1/2"

PVC PIPE

45º ELBOW

"Y" 

CONNECTOR

CHECK
VALVE

1/8" HOLE

DRAIN   TILE

PRO SERIES

PUMP

4

7

5

6

Diagram D

8

1

3

2a

2b

2c

“L”

BRACKET

CAUTION

Содержание 1730 pro series

Страница 1: ...o Outside 4 Connection to Existing Discharge 5 Direct Discharge for Narrow Sumps 6 Connection to Existing Discharge for Narrow Sumps 7 Battery Instructions Preparation of the Battery 8 Control Unit Connections Positioning the Float Switch 9 Connecting the Pump 9 Installing the Battery Fluid Sensor 9 Connecting the Battery 9 Connecting the Charger 9 Understanding the Warning Lights and Alarms Silen...

Страница 2: ...thing In the event of an accident flush with water and call a physician immediately KEEP OUT OF REACH OF CHILDREN To help reduce these risks observe the following precautions Someone should be within range of your voice or close enough to come to your aid when you work near a lead acid battery Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eyes Wear eye a...

Страница 3: ...is system DO NOT use a Pro Series 1000 battery with this system It will not run the pump as long as the Pro Series 2200 battery 1 rigid PVC pipe and fittings PVC primer and cement A union with hose clamps or a Y con nector and two 2 check valves depending on the installation method you use A surge protector recommended Six 6 quarts of 1 265 specific gravity battery acid For narrow sump pits you wi...

Страница 4: ...d above the main AC pump Try to fit the backup pump on the floor of the sump first Make sure there is enough room so the backup pump and the main pump do not touch each other Select the installation method that will best suit your needs from the diagrams at the right Full instructions for each installation method are provided on the following pages Installation will take a couple hours Page 3 NORM...

Страница 5: ...an exterior wall via the shortest path with the fewest turns More turns will reduce the pumping capacity The pipe section exiting the building should be on a downward slope so that the water in the pipe will exit outside instead of returning to the sump pit Be sure to seal the hole in the wall where the pipe exits and prime and cement or clamp all connections securely to prevent leaking When direc...

Страница 6: ...y prevent the pump from operating 4 If there is no check valve on the discharge pipe of the main AC pump one must be installed at this time Cut the discharge pipe approximately one 1 foot above the floor Install a check valve on the top of the pipe and tighten the bottom hose clamp Now prime and cement a small piece of 1 PVC pipe to the bottom of a Y connector Prime and cement the top of the Y ass...

Страница 7: ...e pipe and the details of each installation will vary Using sound plumbing practices try to route the discharge pipe to an exterior wall via the shortest path with the fewest turns More turns will reduce the pumping capacity The pipe section exiting the building should be on a downward slope so that the water in the pipe will exit outside instead of returning to the sump pit Be sure to seal the ho...

Страница 8: ...d cement it to the 1 pipe adapter then screw the adapter into the pump 5 Install a check valve on the top of the PVC pipe attached to the Pro Series pump Make sure it is installed with the arrow pointing up or it will not prevent the backflow of water 6 When a check valve is used a 1 8 hole must be drilled in the PVC pipe above the Pro Series pump Make sure it is above the water line and below the...

Страница 9: ...ttery acid contacts skin or clothing wash immediately with soap and water If acid enters eyes flush with water for 15 minutes and get prompt medical attention Review the safety instructions on page 1 TO FILL THE BATTERY 1 Remove the cover of the battery box by pushing in the tabs on the front and back of the box and lifting up 2 Place the battery box on the floor Place the dry unfilled battery int...

Страница 10: ...at switch will activate the pump when the water raises either float and it will remain running as long as the water is above the float When the water drops below the float switch an internal timer in the control unit will keep the pump running an additional 25 seconds to empty the sump pit The switch should be mounted about six 6 inches above the water level line in the sump pit a Attach the float...

Страница 11: ...rrected the battery should recharge If no other lights are on this means the terminals may be corroded and the battery cannot charge properly Unplug the charger from the wall outlet Then check the battery cables and the battery terminals for corrosion Clean and tighten them as needed The procedure is described in the next column and on page 11 If the battery terminals have been cleaned and the lig...

Страница 12: ...tery Avoid dropping metal tools on the battery If battery acid contacts eyes flush with water for 15 minutes and get prompt medical attention Review the safety instructions on page 1 REFER TO THE PHOTOS AT RIGHT 1 Unplug the charger from the wall outlet 2 Remove the cover of the battery box by pushing in the tabs on the front and back then lifting up 3 Fan the area around the top of the battery wi...

Страница 13: ...OSITIVE post Tighten the wing nuts on the battery posts e Plug the control unit back into the wall outlet 3 a Check the DC fuse by pulling it out of the fuse holder b If the wires are burned and broken replace the fuse with a 20 amp DC safety fuse If the fuse blows again unplug the computer control unit from the wall and disconnect the battery cables from the battery Then call Glentronics technica...

Страница 14: ...ump from the back of the control unit 6 Release the union or check valve and remove the pump and the rigid PVC pipe section from the sump pit 7 Unscrew the pipe and adapter from the old pump and screw them into the new pump 8 Lower the pump into the sump and reconnect the union or check valve 9 Plug the pump wires into the back of the control unit 10 Replace the fluid sensor in the battery Connect...

Страница 15: ...ue buildup from the bottom of the battery cap Replace the cap and fluid sensor 8 Check battery fluid levels PARTS SERVICE INFORMATION You can receive technical support parts or service information by calling Glentronics Inc at 800 991 0466 option 3 or by visiting the Pro Series website at www stopflooding com Send your unit to the following address if repairs are needed Glentronics Inc 645 Heathro...

Страница 16: ...main and backup pipes below the tie in point Make sure check valve is functioning and installed properly Clear the discharge pipe Make sure the 1 8 weep hole is drilled in the discharge pipe below the check valve but above the water line Make sure it is clear of debris Reverse the battery connections Troubleshooting Guide Read safety warnings instructions before attempting any repairs or maintenan...

Отзывы: