appliances  on  the  same  circuit.    Reduce  the
number of appliances on the circuit.

If  all  the  connections  are  secure  and  the  wall
outlet  is  operating,  but  the  “AC  power  failure”
warning light is still on, replace the charger unit
with  the  Pro  Series  part  number  1015001  from
Glentronics at 800-991-0466, option #3.

6

Charging 

The  Pro  Series  1730  is  equipped  with  a
computer-controlled automatic charging system.
The  computer  is  constantly  monitoring  the
battery  and  will  supply  a  pre-programmed
amount  of  energy  to  keep  your  battery  at  full
charge.  The “Charging” light will be on while the
battery  is  charging,  and  off  when  it  is  not
charging.    The  normal  charge  cycle  is  in  one-
hour increments, which increases the life of the
battery and reduces the amount of water loss.  If
the battery is discharged from extended use, the
charger light will remain on until the battery is
completely recharged.

7

System Operating 

This light will always be on when there is power
coming from either the battery or the outlet.

TEST-RESET-SILENCE BUTTON

To test the pump, press the GRAY button on the
front  of  the  control  panel  for  one  (1)  second.
The pump will run for 25 seconds and then shut
off automatically.

To  silence  an  alarm,  press  the  Gray  button  for
one  (1)  second.    Some  alarms  cannot  be
silenced,  since  action  needs  to  be  taken  to
prevent a flood.

To  silence  the  alarms  for  24  hours,  press  the
GRAY button for five (5) seconds until you hear
a buzz.  The alarms will automatically reactivate
in 24 hours.

TESTING THE FLOAT SWITCH

It  is  important  to  manually  test  the  float
switch periodically.

Unplug the main AC pump when installing or
servicing the backup pump to avoid electric
shock.  Failure to do so could cause serious
injury or death.  Review the safety
instructions on page 1.

Lift the float up and let
go.    This  will  activate
the pump.  The control
unit will run the pump
for  approximately  25
seconds  so  it  can
empty  all  the  water  in
the  sump  pit.    While
the  pump  is  active,
water  will  come  out  of  the  1/8”  hole  that  was
drilled  into  the  PVC  discharge  pipe.    This  is
normal.    The  hole  is  needed  to  prevent  an  air
lock  within  the  system.   

DO NOT

obstruct  the

hole or an air lock may prevent the system from
activating.  If  there  is  no  water  in  the  pit,  the
pump can run dry for this amount of time.  The
alarm  will  sound  and  the  “Pump  was  activated”
light  will  go  on.    After  the  pump  has  stopped,
push the GRAY button to silence the alarm.   

BE

SURE  TO  PLUG  IN  THE  MAIN  AC  PUMP  WHEN
YOU HAVE COMPLETED THE TEST.

MAINTENANCE CHECK LIST

Maintenance should be performed 1-2 times per
year

1. Lift the float switch as described at left.

2. Remove all debris from the bottom of the pit.

3. Remove all debris from the water.

4. Remove all debris from the float switch.

5. Fill the pit with water.  Make sure the pump

turns on at the intended level.

6. While  the  pump  is  running,  make  sure  the

pump is evacuating water at a good pace and
water is coming out of the 1/8” air bleed hole.

7. Remove the fluid sensor and yellow cap from

the battery and rinse any residue buildup from
the  bottom  of  the  battery  cap.    Replace  the
cap and fluid sensor.

8. Check battery fluid levels.

PARTS & SERVICE INFORMATION

You  can  receive  technical  support  parts  or
service  information  by  calling  Glentronics,  Inc.
at 

800-991-0466, option #3

, or by visiting the

Pro  Series  website  at 

www.stopflooding.com

.

Send your unit to the following address if repairs
are needed:

Glentronics, Inc., 645 Heathrow Drive,

Lincolnshire, IL 60069-4205

Page 14

LIFT

FLOAT

3

FUSE

CHARGER

PUMP

2

!

DANGER

Limited Warranty

GLENTRONICS,  INC.  warrants  to  the  original  retail  purchaser  that  all  of  its  pump,  switch,  sensor,
battery  box  and  control  unit  products  are  free  from  defective  materials  and  workmanship  for  the
period indicated below:

All parts and labor (excluding installation) for a period of 

three (3) years from the date of purchase

The defective product must be returned directly to the factory, postage prepaid with the original bill
of sale or receipt to the address listed below.  Glentronics, Inc., at its option, will either repair or
replace the product and return it postage prepaid.

CONDITIONS

The unit must be shipped freight prepaid, or delivered, to Glentronics, Inc. to provide the services
described hereunder in either its original carton and inserts, or a similar package affording an equal
degree of protection.

The  unit  must  not  have  been  previously  altered,  repaired  or  serviced  by  anyone  other  than
Glentronics, Inc., or its agent; the serial number on the unit must not have been altered or removed;
the  unit  must  not  have  been  subject  to  accident,  misuse,  abuse  or  operated  contrary  to  the
instructions contained in the accompanying manual.

The  dealer’s  dated  bill  of  sale,  or  retailer’s  receipt,  must  be  retained  as  evidence  of  the  date  of
purchase and to establish warranty eligibility.

This  warranty  does  not  cover  product  problems  resulting  from  handling  liquids  hotter  than  120
degrees  Fahrenheit,  handling  inflammable  liquids,  solvents,  strong  chemicals  or  severe  abrasive
solutions; normal wear; user abuse; misuse, neglect, improper maintenance, commercial or industrial
use; improper connections or installation; damages caused by lightning strikes, excessive surges in
AC  line  voltage,  water  damage  to  the  controller,  other  acts  of  nature,  or  failure  to  operate  in
accordance with the enclosed written instructions.

GLENTRONICS, INC. WILL NOT BE LIABLE FOR ANY INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES
FOR  BREACH  OF  ANY  EXPRESS  OR  IMPLIED  WARRANTIES  ON  THIS  PRODUCT.    SOME  STATES  DO  NOT
ALLOW  THE  EXCLUSION  OR  LIMITATION  OF  CONSEQUENTIAL  OR  INDIRECT  DAMAGES,  SO  THE  ABOVE
LIMITATION MAY NOT APPLY TO YOU.  THIS EXPRESS WARRANTY SHALL BE EXCLUSIVE AND IS IN LIEU
OF ALL OTHER WARRANTIES, WRITTEN OR ORAL, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED
TO ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.  THE CUSTOMER’S
EXCLUSIVE REMEDY FOR BREACH OF THIS WARRANTY, OR OF ANY IMPLIED WARRANTY NOT EXCLUDED
HEREIN, SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE PRODUCT.

For information or service contact:

Glentronics, Inc., 645 Heathrow Drive, Lincolnshire, IL 60069   800-991-0466

Model # PHCC -1730    Serial # ___________________ Purchase Date_________________________

Register online at www.stopflooding.com

Содержание 1730 pro series

Страница 1: ...o Outside 4 Connection to Existing Discharge 5 Direct Discharge for Narrow Sumps 6 Connection to Existing Discharge for Narrow Sumps 7 Battery Instructions Preparation of the Battery 8 Control Unit Connections Positioning the Float Switch 9 Connecting the Pump 9 Installing the Battery Fluid Sensor 9 Connecting the Battery 9 Connecting the Charger 9 Understanding the Warning Lights and Alarms Silen...

Страница 2: ...thing In the event of an accident flush with water and call a physician immediately KEEP OUT OF REACH OF CHILDREN To help reduce these risks observe the following precautions Someone should be within range of your voice or close enough to come to your aid when you work near a lead acid battery Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eyes Wear eye a...

Страница 3: ...is system DO NOT use a Pro Series 1000 battery with this system It will not run the pump as long as the Pro Series 2200 battery 1 rigid PVC pipe and fittings PVC primer and cement A union with hose clamps or a Y con nector and two 2 check valves depending on the installation method you use A surge protector recommended Six 6 quarts of 1 265 specific gravity battery acid For narrow sump pits you wi...

Страница 4: ...d above the main AC pump Try to fit the backup pump on the floor of the sump first Make sure there is enough room so the backup pump and the main pump do not touch each other Select the installation method that will best suit your needs from the diagrams at the right Full instructions for each installation method are provided on the following pages Installation will take a couple hours Page 3 NORM...

Страница 5: ...an exterior wall via the shortest path with the fewest turns More turns will reduce the pumping capacity The pipe section exiting the building should be on a downward slope so that the water in the pipe will exit outside instead of returning to the sump pit Be sure to seal the hole in the wall where the pipe exits and prime and cement or clamp all connections securely to prevent leaking When direc...

Страница 6: ...y prevent the pump from operating 4 If there is no check valve on the discharge pipe of the main AC pump one must be installed at this time Cut the discharge pipe approximately one 1 foot above the floor Install a check valve on the top of the pipe and tighten the bottom hose clamp Now prime and cement a small piece of 1 PVC pipe to the bottom of a Y connector Prime and cement the top of the Y ass...

Страница 7: ...e pipe and the details of each installation will vary Using sound plumbing practices try to route the discharge pipe to an exterior wall via the shortest path with the fewest turns More turns will reduce the pumping capacity The pipe section exiting the building should be on a downward slope so that the water in the pipe will exit outside instead of returning to the sump pit Be sure to seal the ho...

Страница 8: ...d cement it to the 1 pipe adapter then screw the adapter into the pump 5 Install a check valve on the top of the PVC pipe attached to the Pro Series pump Make sure it is installed with the arrow pointing up or it will not prevent the backflow of water 6 When a check valve is used a 1 8 hole must be drilled in the PVC pipe above the Pro Series pump Make sure it is above the water line and below the...

Страница 9: ...ttery acid contacts skin or clothing wash immediately with soap and water If acid enters eyes flush with water for 15 minutes and get prompt medical attention Review the safety instructions on page 1 TO FILL THE BATTERY 1 Remove the cover of the battery box by pushing in the tabs on the front and back of the box and lifting up 2 Place the battery box on the floor Place the dry unfilled battery int...

Страница 10: ...at switch will activate the pump when the water raises either float and it will remain running as long as the water is above the float When the water drops below the float switch an internal timer in the control unit will keep the pump running an additional 25 seconds to empty the sump pit The switch should be mounted about six 6 inches above the water level line in the sump pit a Attach the float...

Страница 11: ...rrected the battery should recharge If no other lights are on this means the terminals may be corroded and the battery cannot charge properly Unplug the charger from the wall outlet Then check the battery cables and the battery terminals for corrosion Clean and tighten them as needed The procedure is described in the next column and on page 11 If the battery terminals have been cleaned and the lig...

Страница 12: ...tery Avoid dropping metal tools on the battery If battery acid contacts eyes flush with water for 15 minutes and get prompt medical attention Review the safety instructions on page 1 REFER TO THE PHOTOS AT RIGHT 1 Unplug the charger from the wall outlet 2 Remove the cover of the battery box by pushing in the tabs on the front and back then lifting up 3 Fan the area around the top of the battery wi...

Страница 13: ...OSITIVE post Tighten the wing nuts on the battery posts e Plug the control unit back into the wall outlet 3 a Check the DC fuse by pulling it out of the fuse holder b If the wires are burned and broken replace the fuse with a 20 amp DC safety fuse If the fuse blows again unplug the computer control unit from the wall and disconnect the battery cables from the battery Then call Glentronics technica...

Страница 14: ...ump from the back of the control unit 6 Release the union or check valve and remove the pump and the rigid PVC pipe section from the sump pit 7 Unscrew the pipe and adapter from the old pump and screw them into the new pump 8 Lower the pump into the sump and reconnect the union or check valve 9 Plug the pump wires into the back of the control unit 10 Replace the fluid sensor in the battery Connect...

Страница 15: ...ue buildup from the bottom of the battery cap Replace the cap and fluid sensor 8 Check battery fluid levels PARTS SERVICE INFORMATION You can receive technical support parts or service information by calling Glentronics Inc at 800 991 0466 option 3 or by visiting the Pro Series website at www stopflooding com Send your unit to the following address if repairs are needed Glentronics Inc 645 Heathro...

Страница 16: ...main and backup pipes below the tie in point Make sure check valve is functioning and installed properly Clear the discharge pipe Make sure the 1 8 weep hole is drilled in the discharge pipe below the check valve but above the water line Make sure it is clear of debris Reverse the battery connections Troubleshooting Guide Read safety warnings instructions before attempting any repairs or maintenan...

Отзывы: