There are two basic methods that can be used to
install  the  pump,  a  direct  discharge  to  the
outside  of  the  building,  or  a  connection  to  an
existing  discharge  pipe.    The  same  two  options
apply in very narrow sump pits where the backup
pump must be mounted above the main pump.

Whenever possible, install your Pro Series backup
pump  with  a  direct  discharge  to  the  outdoors.
By  using  this  method,  there  will  always  be  an
outlet for the water from the sump.  During times
of very heavy rain, many storm sewers fill up.  If
your pump is trying to discharge water into a full
sewer, there is nowhere for the water to go.  By
discharging directly outdoors, there is always an
outlet  for  the  water  that  is  pumped  out  of  the
sump.  For this method, you will need to drill a
hole through a floor joist or the foundation from
the basement to the outside of the house.

If the direct discharge method is not possible or
convenient,  the  Pro  Series  pump  can  be
connected  to  the  same  line  as  your  main  AC
sump  pump  by  installing  a  “Y”  connector  and
two (2) check valves.

In most cases, the backup pump will fit next to
the  main  AC  pump  in  the  sump  pit.    In  very
narrow  pits,  the  backup  pump  can  be  mounted
above the main AC pump.  Try to fit the backup
pump on the floor of the sump first.  Make sure
there  is  enough  room  so  the  backup  pump  and
the main pump do not touch each other.

Select the installation method that will best suit
your needs from the diagrams at the right.  Full
instructions  for  each  installation  method  are
provided on the following pages.

Installation will take a couple hours.

Page 3

NORMAL SUMP PIT

INSTALLATIONS

Installation B
Hookup to
Existing
Discharge Pipe
Page 5

Installation C

Direct Discharge

to Outside

Page 6

Installation D
Hookup to
Existing
Discharge Pipe
Page 7

Installation A

Direct Discharge

to Outside

Page 4

NARROW SUMP PIT

INSTALLATIONS

 

 

PUMP

WIRE

PIPE

 ADAPTER

FLOOR

JOIST

MAIN 
AC PUMP

RIGID

1-1/2"

PVC PIPE

CHECK
VALVE

1/8" HOLE

45º ELBOW

"Y" CONNECTOR

CHECK
VALVE

 PRO SERIES

PUMP

DRAIN   TILE

PUMP WIRE

HOSE CLAMPS

PIPE ADAPTER

"L" BRACKET

FLOOR

JOIST

MAIN
AC PUMP 

RIGID

1-1/2"

PVC PIPE

CHECK
VALVE

RIGID

1-1/2"

PVC PIPE

45º ELBOW

"Y" 

CONNECTOR

CHECK
VALVE

1/8" HOLE

DRAIN   TILE

PRO SERIES

PUMP

PUMP
WIRE

PIPE ADAPTER

DRILL 1/8" HOLE

IF CHECK

VALVE USED

FLOOR

JOIST

MAIN 
AC PUMP

SLOPE

PIPE

DOWN

RIGID

1-1/2"

PVC PIPE

UNION

OR CHECK

VALVE

CHECK
VALVE

 PRO SERIES

PUMP

DRAIN   TILE

PUMP WIRE

CHECK
VALVE

HOSE 
CLAMPS

"L" BRACKET

FLOOR

JOIST

MAIN 
AC PUMP

SLOPE

PIPE

DOWN

RIGID

1-1/2"

PVC PIPE

UNION

OR CHECK

VALVE

   

PIPE ADAPTER

DRILL 1/8" HOLE

IF CHECK

VALVE USED

DRAIN   TILE

PRO SERIES

PUMP

Содержание 1730 pro series

Страница 1: ...o Outside 4 Connection to Existing Discharge 5 Direct Discharge for Narrow Sumps 6 Connection to Existing Discharge for Narrow Sumps 7 Battery Instructions Preparation of the Battery 8 Control Unit Connections Positioning the Float Switch 9 Connecting the Pump 9 Installing the Battery Fluid Sensor 9 Connecting the Battery 9 Connecting the Charger 9 Understanding the Warning Lights and Alarms Silen...

Страница 2: ...thing In the event of an accident flush with water and call a physician immediately KEEP OUT OF REACH OF CHILDREN To help reduce these risks observe the following precautions Someone should be within range of your voice or close enough to come to your aid when you work near a lead acid battery Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eyes Wear eye a...

Страница 3: ...is system DO NOT use a Pro Series 1000 battery with this system It will not run the pump as long as the Pro Series 2200 battery 1 rigid PVC pipe and fittings PVC primer and cement A union with hose clamps or a Y con nector and two 2 check valves depending on the installation method you use A surge protector recommended Six 6 quarts of 1 265 specific gravity battery acid For narrow sump pits you wi...

Страница 4: ...d above the main AC pump Try to fit the backup pump on the floor of the sump first Make sure there is enough room so the backup pump and the main pump do not touch each other Select the installation method that will best suit your needs from the diagrams at the right Full instructions for each installation method are provided on the following pages Installation will take a couple hours Page 3 NORM...

Страница 5: ...an exterior wall via the shortest path with the fewest turns More turns will reduce the pumping capacity The pipe section exiting the building should be on a downward slope so that the water in the pipe will exit outside instead of returning to the sump pit Be sure to seal the hole in the wall where the pipe exits and prime and cement or clamp all connections securely to prevent leaking When direc...

Страница 6: ...y prevent the pump from operating 4 If there is no check valve on the discharge pipe of the main AC pump one must be installed at this time Cut the discharge pipe approximately one 1 foot above the floor Install a check valve on the top of the pipe and tighten the bottom hose clamp Now prime and cement a small piece of 1 PVC pipe to the bottom of a Y connector Prime and cement the top of the Y ass...

Страница 7: ...e pipe and the details of each installation will vary Using sound plumbing practices try to route the discharge pipe to an exterior wall via the shortest path with the fewest turns More turns will reduce the pumping capacity The pipe section exiting the building should be on a downward slope so that the water in the pipe will exit outside instead of returning to the sump pit Be sure to seal the ho...

Страница 8: ...d cement it to the 1 pipe adapter then screw the adapter into the pump 5 Install a check valve on the top of the PVC pipe attached to the Pro Series pump Make sure it is installed with the arrow pointing up or it will not prevent the backflow of water 6 When a check valve is used a 1 8 hole must be drilled in the PVC pipe above the Pro Series pump Make sure it is above the water line and below the...

Страница 9: ...ttery acid contacts skin or clothing wash immediately with soap and water If acid enters eyes flush with water for 15 minutes and get prompt medical attention Review the safety instructions on page 1 TO FILL THE BATTERY 1 Remove the cover of the battery box by pushing in the tabs on the front and back of the box and lifting up 2 Place the battery box on the floor Place the dry unfilled battery int...

Страница 10: ...at switch will activate the pump when the water raises either float and it will remain running as long as the water is above the float When the water drops below the float switch an internal timer in the control unit will keep the pump running an additional 25 seconds to empty the sump pit The switch should be mounted about six 6 inches above the water level line in the sump pit a Attach the float...

Страница 11: ...rrected the battery should recharge If no other lights are on this means the terminals may be corroded and the battery cannot charge properly Unplug the charger from the wall outlet Then check the battery cables and the battery terminals for corrosion Clean and tighten them as needed The procedure is described in the next column and on page 11 If the battery terminals have been cleaned and the lig...

Страница 12: ...tery Avoid dropping metal tools on the battery If battery acid contacts eyes flush with water for 15 minutes and get prompt medical attention Review the safety instructions on page 1 REFER TO THE PHOTOS AT RIGHT 1 Unplug the charger from the wall outlet 2 Remove the cover of the battery box by pushing in the tabs on the front and back then lifting up 3 Fan the area around the top of the battery wi...

Страница 13: ...OSITIVE post Tighten the wing nuts on the battery posts e Plug the control unit back into the wall outlet 3 a Check the DC fuse by pulling it out of the fuse holder b If the wires are burned and broken replace the fuse with a 20 amp DC safety fuse If the fuse blows again unplug the computer control unit from the wall and disconnect the battery cables from the battery Then call Glentronics technica...

Страница 14: ...ump from the back of the control unit 6 Release the union or check valve and remove the pump and the rigid PVC pipe section from the sump pit 7 Unscrew the pipe and adapter from the old pump and screw them into the new pump 8 Lower the pump into the sump and reconnect the union or check valve 9 Plug the pump wires into the back of the control unit 10 Replace the fluid sensor in the battery Connect...

Страница 15: ...ue buildup from the bottom of the battery cap Replace the cap and fluid sensor 8 Check battery fluid levels PARTS SERVICE INFORMATION You can receive technical support parts or service information by calling Glentronics Inc at 800 991 0466 option 3 or by visiting the Pro Series website at www stopflooding com Send your unit to the following address if repairs are needed Glentronics Inc 645 Heathro...

Страница 16: ...main and backup pipes below the tie in point Make sure check valve is functioning and installed properly Clear the discharge pipe Make sure the 1 8 weep hole is drilled in the discharge pipe below the check valve but above the water line Make sure it is clear of debris Reverse the battery connections Troubleshooting Guide Read safety warnings instructions before attempting any repairs or maintenan...

Отзывы: