5. Ant (Antenna) B
This SMA connector is attached internally to the mobile phone module. The
supplied antenna should be connected to this connector. For best results it is
advisable to place the 2 antennas as far apart as practical and in areas of good
cell phone reception.
6. Dante® Ethernet Connector
If fitted this Neutrik Ethercon Ethernet connector provides 4 x bi-directional
Dante®/ AES67 network audio circuits. The 4 circuits are split 2 for each phone
module.
The audio output circuits to the network are in parallel with the rear panel Line out
XLRs and the handset interfaces’ earpiece.
The audio inputs to the phone from the network are mixed together with the Line
in XLR input and the mouthpiece of the handset interface.
Please note the Dante Network interface board is an optional item and is only
fitted if by Glensound if ordered at the same time as the GS-MPI005HD MKII. It is
possible to order this interface and fit it retrospectively yourself at a later date.
7. Handset Interface
This connector allows a normal analogue telephone handset to be connected to
the GS-MPI005HD MKII.
Once connected the handset can be used to answer calls (when an incoming call
is received just pick up the handset to answer). If used like this then the phone
call’s audio will only be present on the handset and not the rear panel XLRs (or
Dante Broadcast Interface).
To transfer audio between the handset and XLR/ network interface use the on-
screen divert symbol.
8. DC Loops
This 9 pin female D connector provides 5 general purpose inputs/ outputs.
Using the GPIO menu on the touch screen each of the 5 circuits can be set to
either an input or an output and their functionality can be assigned.
9. Mains
A standard IEC plug is fitted for powering the unit by a mains supply. The
attached mains circuit MUST supply an earth.
An internal fuse is fitted to protect the unit and a filtered IEC plug is used.
The GS-MPI005HD MKII can operate on mains voltages between 100
– 240 VAC