background image

C

ABLEMASTER

W

IRING

I

NSTRUCTIONS

(

CON

T

.)

T

HE

CM-7 

AND

CM-8 

POWER UNITS

are wired through an integral

relay  assembly  for  12  or  24  volt  DC  depending  on  your  boat’s

voltage. The voltage for each 

Cablemaster

is located on the unit’s

label. The 

Cablemaster

should be connected to a separate circuit

breaker of appropriate amperage (see Fig. 9) on the main or aux-

iliary DC electrical distribution panel. In addition to providing elec-

trical  “overload”  protection,  a  separate  breaker  for  the

Cablemaster

allows the unit to be turned “OFF” thus preventing

the  unauthorized  use  of  the  unit  when  the  boat  is  unattended.

This is especially important if the switch is located where it can

easily be actuated by children on board.

Be sure to observe the proper polarity when connecting the DC

imput wires.

Both the limit switches are designed to automatically stop the

motor when the cable has reached it’s limit of travel. The in-limit

switch is located in the hawse pipe gasket ring and is covered by a neoprene cover to shield it from moisture. The in-limit

switch, which is connected to the #4 and #5 terminals on the relay assembly, is activated when the plug cover touches the

switch.

The out-limit switch, which is connected to the #6 and #7 terminals of the relay assembly, is located in the guide roller

assembly mounted on the lower side of the power unit and is activated by a nylon safety collar secured near the terminal

end of the shore power cable. The collar, which acts as a positive mechanical “stop” as well as a means to  activate the

out-limit swithces, would be fitted around the shore power cable at a point that allows adequate slack in the cable for

unstrained AC electrical connections (The same collar is used for 6/3 or 6/4 cable). If the shore power cable is being direct-

ed through the vertical pipe extension, it is necessary to relocate the guide roller assembly with the out-limit switch from

the power unit to the lower end of the vertical pipe and to reconnect the out-limit switch using the appropriate lengths of

wire (NOTE: Failure to install the nylon safety collar and rewire the out-limit switch can result in damage to the shore power

cable’s electrical connection).

The 3 conductor cable for the power switch is color coded to correspond with the terminal strip on the relay assembly.

For convenience and ease of operation, the power switch should be mounted near the hawse pipe or in the appropriate

hole with the optional bezel (see accessories). In each case, the power switch must be protected by the neoprene cover

to prevent the intrusion of moisture.

The relay box is mounted on a sub-plate and may be attached to the power unit cover screws in two ways (see label on

sub-plate). This provides easy access in making wiring connections. If desirable, it may also be mounted on a bulkhead

close by to the power unit making sure that the connecting wires are fastened away from the pulley and rollers.

NOTE 1: On installation of the CM-7 or CM-8 Cablemaster, convenient

temporary operation or remote control of the Cablemaster by the installer

may be desirable. With the power switch, limit swithes and battery con-

nected, first jumper #1 and #2 to retract cable, then jumper #1 and #3 to

extend cable. This enables the installer to directly supervise the coiling of

the cable at the storage area. Remove when Cablemaster installation is

complete.

NOTE 2: Do not attach voltage wires to the motor wires while  they are

still fastened to the barrier strip. This will cause a short in the relay assem-

bly. Remove the motor wires from the barrier strip then connect battery

power to the motor wires for check-out of motor operation.

D

12

7

W

IRING THE

CM-7 

OR

CM-8 C

ABLEMASTER

10"

(254mm)

13"

(330mm)

24"

(610mm)

13"

(330mm)

17-7/8"

(454mm)

  6 1/2"

(165mm)

CM-4 DIMENSIONS

Specifications:

Voltage:

Amperage:

Dimensions:

Weight:

Capacity:

Length of cable:

12v DC or 24v DC

4-5 amps under load

5-1/2” L x 6” W x 10” H

(power unit only)

9 lbs.

30amp 110 volt cable 3/4” diameter

determined by available storage space

* Storage Container not included

Red    1

White  2

Black  3

Power

Switch

Pos.  +

Neg.  -

12 / 24v 

DC Input

Motor 

Output

CABLEMASTER RELAY ASSEMBLY

 #  04034    (12, 24 volt DC)

  12v DC use 20 amp breaker

24v DC use 5 amp breaker

 OUT

 OUT

 Limit

Switch

Switch

(Remote - RED)

(Remote - BLACK)

Orange

Black

GLENDINNING MARINE PRODUCTS, INC.

   Conway, SC   843-399-6146

           4

           4

           5

           5

           6

           7 

   IN

 Limit

Switch

(Rmt - Green or Tan)

(Rmt - Yellow or Purple)

ORANGE

BLACK

OFF

OUT

IN

POWER

SWITCH

RED

WHITE

BLACK

IN-LIMIT

SWITCH

OUT-LIMIT

SWITCH

M

12

!

or

!

24v

MOTOR

BATERY

!

POSITIVE

!

(+)

BATTERY

!

NEGATIVE

!

(-)

WHITE

RED

BLACK

T

YPICAL

CM-7 / CM-8 R

ELAY

A

SSEMBLY

W

IRING

Installer needs only to attach 

battery power to relay assembly

12 or 24v

MOTOR

V

24v

Red    1

White  2

Black  3

Power

Switch

Pos.  +

Neg.  -

12 / 24v 

DC Input

Motor 

Output

CABLEMASTER RELAY ASSEMBLY

 #  04034    (12, 24 volt DC)

  12v DC use 20 amp breaker

24v DC use 5 amp breaker

 OUT

 OUT

 Limit

Switch

Switch

(Remote - RED)

(Remote - BLACK)

Orange

Black

GLENDINNING MARINE PRODUCTS, INC.

   Conway, SC   843-399-6146

           4

           4

           5

           5

           6

           7 

   IN

 Limit

Switch

(Rmt - Green or Tan)

(Rmt - Yellow or Purple)

ORANGE

BLACK

OFF

OUT

IN

POWER

SWITCH

RED

WHITE

BLACK

IN-LIMIT

SWITCH

OUT-LIMIT

SWITCH

M

12

!

or

!

24v

MOTOR

BATERY

!

POSITIVE

!

(+)

BATTERY

!

NEGATIVE

!

(-)

WHITE

RED

BLACK

12 or 24v

MOTOR

Jumper

#1 & #2

for IN

Jumper

#1 & #3

for

OUT

Jumper wires must be attached to #4 & #5, and #6 & #7

if IN Limit and OUT Limit Switches are not connected

NOTE 1

Содержание Cablemaster

Страница 1: ...Conway SC 29526 Phone 843 399 6146 Fax 843 399 5005 www glendinningprods com G G G G L L L LE E E EN N N ND D D DI I I IN N N NN N N NI I I IN N N NG G G G C CABLEMASTE ABLEMASTER R Shore Power Cable...

Страница 2: ...nsists of two major components the hawse pipe and power unit The chromed hawse pipe is designed to accommodate varying sizes of shore power cables with the attached 30 or 50amp shore power plug cover...

Страница 3: ...ble The CM 4 usually comes attached to it s own storage container to make installation as easy as possible You may also order the CM 4 with TV telephone cable installed instead of 30 amp shore power c...

Страница 4: ...so be careful to remember that the selection of the hawse pipe location is in a large measure determined by the prop er location of the power unit and cable storage area Be sure that the hawse pipe s...

Страница 5: ...limit switch by extending the wire to the relay box Fig 4 OTHER INSTALLATION OPTIONS Any number of mounting arrangements can be accomplished using the PVC pipe to remote mount the power unit or guide...

Страница 6: ...gh a PVC pipe you are now ready to wire the Cablemaster to the boat s DC electrical system If the shore power cable is being direct ed vertically through PVC pipe see drawing below it is necessary to...

Страница 7: ...limit swithch which is connected to the 1 and 2 terminals on the barrier strip is activated when the plug cover touch es the switch The out limit switch which is connected to the 3 and 4 terminals of...

Страница 8: ...or in the appropriate hole with the optional bezel see accessories In each case the power switch must be protected by the neoprene cover to prevent the intrusion of moisture The relay box is mounted o...

Страница 9: ...con nection to the electrical system E CABLE ADJUSTMENT Shore power cable diameters vary from one cable manufacturer to another the Cablemaster s main pulley is split in half and proper friction adjus...

Страница 10: ...xes receptacles breakers and other enclosures in which electrical connections are made should be waterproof or be installed in a protected area Electricity enters the boat through the power cable The...

Страница 11: ...l either no power or unit has power and does not respond Tripped breaker Power wire incorrectly connect ed to relay assembly Defective motor Defective relay box Reset breaker Replace relay assembly Wi...

Страница 12: ...mp 220 v Adjustable 7 8 1 1 4 dia Length capacity Determined by size of storage location CM 7 DIMENSIONS 5 5 127 mm Hawse Pipe Flange Dim 5 x 6 1 2 3 1 2 89 mm 4 3 4 121 mm 9 3 4 248 mm 15 3 4 400 mm...

Страница 13: ...DIMENSIONS Specifications Voltage Amperage Dimensions Weight Capacity Length of cable 12v DC or 24v DC 4 5 amps under load 5 1 2 L x 6 W x 10 H power unit only 9 lbs 30amp 110 volt cable 3 4 diameter...

Страница 14: ...8 3 8 213 mm 4 102 mm SPECIFICATIONS Voltage 12v DC 24v DC available Current 7 11 Amps under load Weight 40 lbs Power unit 12 lbs Hawse pipe Cable size up to 2 gauge 5 conductor 100amp Adjustable 1 32...

Страница 15: ...ASSEMBLY 50421 HINGE 50420 CAP RELAY ASSEMBLY 04034 12 24 VOLTS 70005 U BOLT 2X 65001 Spacer 50415 CHASSIS COVER 50414 CHASSIS 04812 IN LIMIT SWITCH ASSY incl switch 2 ft wire assy protective boot 048...

Страница 16: ...mt Yellow or Purple ORANGE BLACK OFF OUT IN POWER SWITCH RED WHITE BLACK IN LIMIT SWITCH OUT LIMIT SWITCH M 12 or 24v MOTOR BATERY POSITIVE BATTERY NEGATIVE WHITE RED BLACK CABLEMASTER WIRING DIAGRAM...

Страница 17: ...DINNING MARINE PRODUCTS INC for instructions concerning removal and shipping of the defective component Upon compliance of the foregoing procedure all warranted defects will be repaired or at GLENDINN...

Страница 18: ...ge of transmitter Relay Unit required for addition of Remote on CM 4 models 85448 85424 85420 85421 POWER CABLE STORAGE CONTAINERS rotationally molded styrene containers used to store shore power cord...

Страница 19: ...DOUS MISUSE CAN RESULT IN FIRE OR DEATH BY ELEC TRICAL SHOCK PLEASE READ CAREFULLY AND FOLLOW INSTRUCTIONS HAZARDS STATEMENT N OR SEND VIA FAX TO 843 399 5005 A cord reel marked for indoor use is to b...

Страница 20: ...SML CMMAN PRINT DATE 06 08 740 CENTURY CIRCLE CONWAY SC 29526 8274 USA PRODUCT WARRANTY INFORMATION PLACE STAMP HERE Diameter 3 5 8 cut on outside of line Diameter 17 64 4 Plcs Hawse Pipe Template...

Отзывы: