Supplied By www.heating spares.co Tel. 0161 620 6677
Page 24
Page 25
SY
STEMA
TE
2000
2.0 INSTALLATION
2.2 INSTALLATION
Electrical Power Supplies - SysteMate
2000
with Switch.
A heavy duty electrical supply, see table on
page 16, is required for this model and we
recommend that a fully qualified electrician
must undertake this work.
The electrical installation must comply with
the IEE Requirements for Electrical Installations
BS 7671.
Note: do not attempt the electrical work
unless you are competent to carry it out to
the above standards.
A 10.0mm
2
power cable is fitted with a 3 metre
tail for the installer to connect to an isolator
which must not be more than 2 metres away
from the appliance.
A schematic arrangement of the internal wiring
is shown on page 24.
All terminals are labelled.
Before commencing check that the power
supply source (i.e. isolator) is in accordance
with section 1.2 Site Requirements and ensure
it is isolated.
Run the 10mm
2
cable provided through the
service slot provided in the base of appliance
and connect to the isolator as follows:-
red • live
black • neutral
green/yellow • earth
Check the cables are secure in the grips
provided below the terminal strip and ensure
they are not in contact with any hot surfaces.
The recommendations contained under
Electrical Connection - Standard Appliance
should be followed when connecting a remote
clock, room thermostat, boiler etc.
WARNING : DO NOT SWITCH ON ELECTRIC
BACKUP, IF FITTED, UNTIL THE APPLIANCE
HAS BEEN FULLY COMMISSIONED i.e.
PRIMARY STORE IS FILLED AND VENTED.
WARNING
: IF THE SYSTEMATE IS FITTED WITH AN OPTIONAL ELECTRIC
BACKUP SYSTEM I.E. ‘SWITCH’.
IMPORTANT
: ELECTRICIAN/INSTALLER PLEASE NOTE.
THE 2 x 25A FUSES FOR THE ‘SWITCH’ ELECTRIC BACKUP SYSTEM ARE
SUPPLIED IN THE ACTIVE FUSE CARRIER. THE GAS BOILER CAN BE
COMMISSIONED WITHOUT INSERTING THESE FUSES.
IT IS IMPORTANT THAT THE GAS BOILER IS COMMISSIONED BEFORE TESTING
OR USING EMERGENCY SWITCH FACILITY.
AFTER THE GAS BOILER HAS BEEN COMMISSIONED CUT AND REMOVE THE
PLASTIC TIE AND PUSH DOWN FULLY THE CARRIAGE TO COMMISSION THE
SWITCH FACILITY.
Содержание SysteMate 125
Страница 8: ...Supplied By www heating spares co Tel 0161 620 6677 Page 8 1 0 DESIGN 1 2 TECHNICAL DATA ...
Страница 31: ...Supplied By www heating spares co Tel 0161 620 6677 Page 31 SYSTEMATE 2000 3 0 SERVICING ...
Страница 40: ...Supplied By www heating spares co Tel 0161 620 6677 Page 40 ...
Страница 41: ...Supplied By www heating spares co Tel 0161 620 6677 ...
Страница 42: ...Supplied By www heating spares co Tel 0161 620 6677 ...
Страница 43: ...Supplied By www heating spares co Tel 0161 620 6677 ...
Страница 44: ...Supplied By www heating spares co Tel 0161 620 6677 ...