Page 8
Connection Details/Dimensions For Top Of Unit
Figure 1.4
95
148
156
103
Open Vent (22mm)
Cold Feed (22mm)
Connection Details/Dimensions For Bottom Of Unit
Mains Cold Water Inlet (15mm/22mm)
Hot Water Outlet (18mm/22mm)
70
35
546
558
Plan Of Appliance Connections
The PulsaCoil Stainless units are supplied on
an installation base to allow the pipe runs to
connect to the appliance from any direction.
It is easier if all pipes protrude vertically in the
cut out area shown. Compression or push fit
connections can be used. All pipe positions
are approximate and subject to a tolerance of
+/- 10mm in any direction. Space will also be
required for a 15mm cold water supply and a
22mm warning / overflow pipe (if the optional
extra ball valve and overflow connector have
been specified. If a warning/overflow pipe
is NOT provided the F&E Cistern should be
filled from a temporary hose connection
incorporating a double check valve. This can
be from a temporary hose connection supplied
from a cold water tap or a permanent cold
branch provided adjacent to the Top up Cistern.
The temporary connection must be removed
once the appliance is filled.
Note: All dimensions are shown in mm and
are to the centre line of the pipework.
DESIGN
TECHNICAL DATA