background image

12

Declaration of Conformity 

(Directive 2006/95/EEC and EMC directive 2004/108/EEC and  

ATEX directive 94/9/EEC) 

Manufacturer: 

 

Glamox ASA 

Adress: 

  Birger 

Hatlebakksveg15 

    N-6405 

Molde 

    NORWAY 

Product: 

 

 

Recessed Ex Luminaires for fluorescent lamps 

Product name:

 

TX20-R series and TX20-R -E series 

 

 

 

 

 

II2G     Ex e d mb IIC T4 

      

We declare under sole responsibility that above listed products confirms with the standards 
listed. 

Reference 

  Date 

of 

issue 

 Name 

IEC/EN 60079-0 

 

2004   

 

General requirements (Ex) 

IEC/EN 60079-7 

 

2006   

 

Increased safety (Ex-e) 

IEC/EN 60079-1 

 

2004   

 

Flameproof enclosure (Ex-d) 

IEC/EN 

60079-18 

 2004 

  Encapsulation 

(Ex-m) 

EN 

60598-1 

  2008 

  General 

requirements 

(lighting)

EN 

60598-2-2 

  1997 

  Luminaires 

for 

recessed 

mounting 

EN60598-2-22  2008 

  Emergency 

luminaires 

EN 

61000-3-2 

  2006 

  EMC-Harmonic 

currents 

EN 

61547 

  1995/A1:2000 

 EMC-Immunity 

requirements 

EN 

55015 

  2006 

  EMC-Emission 

requirements 

IEC 

60068-2-6  1982 

  Vibration 

IEC 60092-306 

 

1982   

 

Electrical installations in ships 

Place and date: 

Molde, 08. Mar. 2010 

Name and signature of 
autorized persons: 

            
    Robert 

Svendsen 

  

 Geir 

Sylte 

    Factory 

Manager 

  Laboratory 

Manager 

Содержание aqua signal TX20 Series

Страница 1: ...SERVICE MANUAL TX20 effective solutions for Ex Zones ...

Страница 2: ...aiseen virtalähteeseen Tämä voi vioittaa elektroniikkaa DE Nicht an unsauberes Netz Baustrom anschliessen Die elektronischen Bauteile können dadurch beschädigt werden WASTE HANDLING This is an electric product and shall not be collected together with other type of waste but be delivered to a disposal for this type of products Glamox ASA er medlem i RENAS som administrerer en innsamlings og behandl...

Страница 3: ... E or 0 28A 2 x 28W E Power factor 0 96 Light tube type T16 T5 14W 28W Other markings CE0470 137 L C1 B 130 Product B B1 L L1 C1 TX20 RS3 214 320 614 410 TX20 RS3 228 320 1214 1010 TX20 RC3 214 282 263 614 590 410 TX20 RC3 228 282 263 1214 1190 1010 TX20 RW3 214 312 263 614 590 410 TX20 RW3 228 312 263 1214 1190 1010 TX20 RT3 214 297 597 410 TX20 RT3 228 297 1197 1010 TX20 RL3 214 305 614 410 TX20...

Страница 4: ...4 TX20 R PART NO C60052395 A B C D E ...

Страница 5: ...5 TX20 R A ...

Страница 6: ...6 TX20 R alternative suspension 0 70 mm 70 130 mm ...

Страница 7: ...7 NB TX20 R B D ...

Страница 8: ...8 TX20 R C C ...

Страница 9: ...9 CLICK TX20 R ...

Страница 10: ...d steel plate Material cover LEXAN 500 R colour RAL9016 Cable MPRX 3 x 1 5 mm2 1 4 m Cable entry BRASS GLAND M20 Ex e 8 13 Temperature limits ta 30ºC to 50ºC Protection IP65 Other markings CE0470 Ø126 108 85 15 175 TX20 R Battery box for recessed intallation Ø128 Spare battery Glamox part no TX20062321 8 4V or TX20062324 4 8V ...

Страница 11: ...t ceilings are RS3 Shadow panel ceiling 300 mm width 275 mm 25 mm 25 mm RL3 Shadow panel ceiling 300 mm width 280 mm 20 mm 15 mm RC3 Concealed modular ceiling or solid ceiling Frame 282 mm wide RC4 Concealed modular ceiling or solid ceiling Frame 357 mm wide RW3 Wide panel ceiling 312 mm width RT3 T profile ceiling 297 mm width RT6 T profile ceiling 597 mm width RS3 275 25 25 RC4 357 RT3 297 RC3 2...

Страница 12: ...0079 0 2004 General requirements Ex IEC EN 60079 7 2006 Increased safety Ex e IEC EN 60079 1 2004 Flameproof enclosure Ex d IEC EN 60079 18 2004 Encapsulation Ex m EN 60598 1 2008 General requirements lighting EN 60598 2 2 1997 Luminaires for recessed mounting EN60598 2 22 2008 Emergency luminaires EN 61000 3 2 2006 EMC Harmonic currents EN 61547 1995 A1 2000 EMC Immunity requirements EN 55015 200...

Страница 13: ... Line voltage 110 127V or 220 250V 0 50 60 Hz Supplied current mains mode230 0 14A 2 x 14W 0 21A 3 x 14W or 0 27A 2 x 28W 0 14A 2 x 14W E 0 22A 3 x 14W E or 0 28A 2 x 28W E Power factor 0 96 Light tube type T16 T5 14W 28W Other markings CE0470 L C1 129 100 B C E B L C C1 E TX20 S 214 240 573 75 410 80 TX20 S 228 240 1173 75 1010 80 TX20 S 314 315 573 150 410 158 X Condition for safe use TX20 S ...

Страница 14: ...14 TX20 S ...

Страница 15: ...15 CLICK TX20 S ...

Страница 16: ...79 0 2004 General requirements Ex IEC EN 60079 7 2006 Increased safety Ex e IEC EN 60079 1 2004 Flameproof enclosure Ex d IEC EN 60079 18 2004 Encapsulation Ex m EN 60598 1 2008 General requirements lighting EN 60598 2 1 1989 General purpose luminaires EN60598 2 22 2008 Emergency luminaires EN 61000 3 2 2006 EMC Harmonic currents EN 61547 1995 A1 2000 EMC Immunity requirements EN 55015 2006 EMC Em...

Страница 17: ...SION ROD 1 pcs 0 3 0 6 m Part no 79000020 TX20 R SUSPENSION ROD 1 pcs 0 6 1 0 m Part no 79000030 214 E1 5 Part no 19596547 314 E1 5 Part no 19596514 228 E1 5 314 E3 0 Part no 19596501 228 E3 0 External battery 214 E1 5 Part no TX20062324 314 E1 5 228 E1 5 214 E3 0 Part no TX20062321 314 E3 0 228 E3 0 Integrated battery ...

Страница 18: ...thed in the terminal block It can also be earthed exter nally to the contact on the luminaire house The shielded cable must be earthed as in figure 1 Earthing of earth wire 2 Earthing of cable shield N 1 2 3 2 L1 L4 TX20 installation Battery connection see page 8 Mains L N L4 3 N L1 2 L4 3 N L1 2 L4 3 N L1 2 HF E HF E HF Wiring with 1 poled switch for main light Mains L N L4 3 N L1 2 L4 3 N L1 2 H...

Страница 19: ...19 ...

Страница 20: ...rror No Light in LED No power or malfunction of the emergency unit Cables Mains supply cable must be approved for fixed installation The external diameter should be 8 13 mm M20 gland or 12 19 mm M25 gland Cross sectional area of the wires should be between 1 5 and 6 0 mm The cable must have an earth wire and a shielded cable is recommended Operation of TX20 HF without emergency light TX20 without ...

Страница 21: ...s too low 1 Clean the cover of the luminaire 2 Change the tube or battery D Em light does not last specified time 1 5 or 3 hours for standard luminaire 1 Change the battery MAINTENANCE TX20 has long lifetime and a minimum need for maintenance However it may be necessary to clean the cover of the luminaire if it gets dirty or change the NiCd battery after 4 to 6 years in order to maintain the speci...

Страница 22: ...er and dry with a clean cloth Caution Organic solvent based or strong alkalic detergents should be avoided as they can damage components over a long period of time and especially components made from synthetic materials Reflector For cleaning high lustre aluminium we recommend the use of a soft clean cloth without any washing detergent additive Be aware that high lustre aluminium can be very sensi...

Страница 23: ...ä HFlaitteen käyttöikää Käyttöikä HF laitteen ympärillä olevan ilman lämpötila ja verkkovirran laatu vaikuttavat laitteen käyt töikään Nimellinen käyttöikä on 50 000 tuntia kun ympäröivän ilman lämpötila on valaisimeen merkitty TA lämpötila Tänä aikana kuitenkin n 10 laitteista voi tuhoutua Jännitepiikit ja muutokset kuten myös kytkeminen väliaikaiseen virtalähteeseen vähentävät voimakkaasti odote...

Страница 24: ... 8673 6067 Fax 86 411 8673 6157 www glamox com Glamox Lighting Co Ltd Shanghai Tel 86 21 5187 2358 Fax 86 21 5161 0360 www glamox com Singapore Glamox Far East Pte Ltd Tel 65 6748 1977 Fax 65 6742 9711 gfe1026 singnet com sg www glamox com North America Mariteam Lighting Inc Canada Tel 1 709 753 2373 Fax 1 709 753 2180 sales mariteamusa com www mariteam com Mariteam Lighting Inc USA Tel 1 713 690 ...

Отзывы: