LED leading edge phase control: Reduce the connected load. Check operation in the LED
trailing edge phase control setting. Exchange lamps for another type.
Let device cool down for at least 15 minutes.
Switch circuit breakers and device on again.

Cause 2: Surge protection has triggered.

LED trailing edge phase control: Check operation in the LED leading edge phase control
setting, reduce connected load as well if necessary.
Exchange lamps for another type.

Cause 3: short-circuit protection has tripped.

Disconnect device from mains by switching off circuit breaker.
Eliminate short-circuit.
Switch circuit breakers and device on again.

Short-circuit protection is not based on a conventional fuse, no metallic separation of the
operational current.

Cause 4: load failure.

Check load, replace light bulb. For inductive transformers, check primary fuse.

LED lamp is dimly lit when device is switched off

Cause: LED lamp is not suitable for this device.

Use a compensation module, see accessories.
Use another type of LED lamp or an LED lamp of another manufacturer.

Device has no function

Device is operated with a room temperature controller cover and electrothermal actuator and
the neutral conductor is not connected.

Connect a neutral conductor.

7

Accessories

Compensation module LED

Order no. 2375 00

8

Warranty

The warranty is provided in accordance with statutory requirements via the specialist trade.
Please submit or send faulty devices postage paid together with an error description to your re-
sponsible salesperson (specialist trade/installation company/electrical specialist trade). They will
forward the devices to the Gira Service Center.

6 / 7

82400512

24.05.2019

Содержание 5405 00

Страница 1: ...halogen lamps electronic or inductive transformers with halogen or LED lamps switchable or dimmable HV LED or compact fluorescent lamps electrothermal actuators in combination with room temperature c...

Страница 2: ...on the main device Switch load Press the button cover The load is switched on or off 3 wire extension Press top to switch on press bottom to switch off 4 Information for electrically skilled persons...

Страница 3: ...c overheating or short circuit protection has been activated separate the switch insert from the grid for a few minutes 4 2 Commissioning Operation with neutral conductor The device is powered via the...

Страница 4: ...oad is switched off Press button Test 1 for longer than 4 seconds until LED 2 lights up Figure 3 Assignment of LED colour for the operating mode Keep pressing button Test 1 for less than 1 second unti...

Страница 5: ...rotary dimmer extension 10 Total line length Extension max 100 m pwr cable max 100 m 6 Troubleshooting Connected lamps flicker Cause the specified minimum load is below the set level Increase the conn...

Страница 6: ...ation of the operational current Cause 4 load failure Check load replace light bulb For inductive transformers check primary fuse LED lamp is dimly lit when device is switched off Cause LED lamp is no...

Страница 7: ...ersiepen GmbH Co KG Elektro Installations Systeme Industriegebiet Mermbach Dahlienstra e 42477 Radevormwald Postfach 12 20 42461 Radevormwald Deutschland Tel 49 0 21 95 602 0 Fax 49 0 21 95 602 191 ww...

Отзывы: