The Reporting Page
can be used to select:-
Report Format
USERDEF
, FULL or NMEA
Select Parameters to Report
Report FULL will set the MaxiMet to report default parameters (example show GMX600 report):-
NODE,DIR,SPEED,CDIR,PRESS,RH,TEMP,DEWPOINT,PRECIPT,PRECIPI,TIME,VOLT,STATUS.
Report parameters can be selected in any order or on or off in USERDEF setting.
NODE
Output Node letter.
DIR
Outputs wind direction readings.
SPEED
Outputs wind speed readings.
CDIR
Outputs Compass corrected wind direction readings.
PRESS
Outputs the Barometric Pressure reading.
RH
Outputs Relative Humidity reading.
TEMP
Outputs the Temperature reading.
DEWPOINT
Outputs the Dewpoint reading.
PRECIPT
Outputs Precipitation (Rain) Total reading, this is an accumulated rain reading
updated at the output rate.
Is set to zero on MaxiMet power up.
Is set to zero when the clock reads 23:59:59 to 00 (midnight) if Automatic
Reset of Total Precipitation is set to ON (default setting).
PRECIPI
Outputs Precipitation (Rain) Intensity. It is the sum of the last sixty lots of 1
minute accumulated Rain data. A new sum measurement is generated every
minute.
TIME
Outputs Date and Time.
VOLT
Outputs the MaxiMet Supply Voltage.
STATUS.
Outputs the MaxiMet Sensors Status Code (see page 64).