Page 3-1
VaporTEK Pump
VaporTEK System Description
MDE-5394B VaporTEK™/VaporTEK-3 Controller Board 110 V UL® Vapor Recovery Collection System for Encore® 500 S
Start-Up and Service Manual · March 2019
3 – VaporTEK System Description
VaporTEK Pump
The VaporTEK pump is a variable-speed piston pump capable of drawing up to
120 LPM of vapor through a vapor recovery nozzle and delivering it to the UST at the
dispensing site. The piston pump works on the floating piston principle, i.e., piston rod and
piston form a rigid unit. On each complete rotation of the shaft, the gas mixture is aspirated at
the inlet valve and compressed in the cylinder. The inlet or outlet valve blocks a flow
direction, i.e., the aspirated gas mixture is expelled via the outlet side of the pump.
The following are the features/requirements of the VaporTEK pump:
• The ambient and the inlet temperature must not exceed 130 °F (55 °C).
• The gas temperature in the outlet line must not exceed 203 °F (95 °C).
• The maximum pressure with closed discharge shall not exceed 1600 mbar (g) at any
speed.
• The inlet/outlet ports have standard National Pipe Thread (NPT) 3/8-inch female threads.
Technical Considerations (Not for Field Representative’s Use):
Use - For use only in products where the acceptability of the combination is determined by
Underwriters Laboratories (UL) LLC.
The following are the conditions of acceptability:
1
When mounted in the end-use application, these assemblies are not to be supported by any
fluid handling pipes. The suitability of the mounting means of the device are to be reviewed in
the end-use.
2
These devices are intended for use as part of a Listed retrofit assembly or as a factory installed
component for Listed power-operated flammable liquid dispensing devices.
3
The suitability of the grounding means of this device with respect to UL 79 Ninth Edition,
shall be evaluated in the end-use.
4
These pumps are intended to be mounted to the inside of a dispenser housing. Consideration
should be given to the need for guards to restrict access to moving parts in the end use.
5
This pump has not been evaluated for outdoor use.
Do not install piping that can stress the pump housing.
WARNING