Status and diagnostic information
Gigaset T440 PRO / Gigaset T640 PRO / Admin Guide INT en / A31008-N2003-R103-2-7620 / status.fm / 6/26/17
Status and diagnostic information
The
System status
menu has detailed information on the status of the PABX, the connections
and interfaces, and diagnostic information. You can restart or shut down the system if required.
General information
¤
Administration
System status
General information
General information:
Software version
,
Licence state
,
System date and time
,
System uptime
,
CPU load
,
Memory state
,
Disk state
,
Number of users
,
Number of phones
Interfaces
¤
Administration
System status
Interfaces
The screen shows on a diagram the status of the PABX interfaces (connections).
Information on ISDN connections: BRI (digital modules)
Disabled
Not connected.
Active - OK
Connected and ready.
RAI alarm
Remote Alarm Indicator: is sent by a terminal when the input signal
is lost.
LOS/LOF alarm
LOS (loss of signal): Fault message when a network component
ascertains the loss of the input signal.
LOF (loss of framing): Fault message when an ATM receiver station
loses the frame description. It is used to monitor the performance of
the bit transmission layer in frame-oriented networks.
AIS alarm
AIS (Alarm Indication Signal): Fault message when a transmission
error is detected in the transmission channel, or a fault message is
received by another unit on the transmission path.
D-channel alarm Fault on the D-channel (used to transmit control information).
NFAS alarm
NFAS (Non-Facility Associated Signalling): Signalling protocols sent
over a link completely independent of the carrier channel.