7DX(R)+/7DXE Motherboard
65
Rebuilding A Mirrored Array
The Rebuild Array <5> Menu option is necessary to recover from an error in a mirrored disk
array. You will receive an error message when booting your system from the BIOS.
NOTE: Drives MUST be replaced if they contain any physical errors.
Follow these steps BEFORE using the Rebuild Array menu option:
1. On bootup, the system Startup BIOS will display an error message identifying which drive
has failed.
2. Press <Ctrl-F> keys to enter FastBuild Main Menu.
3. Select submenu Define Array <3>.
4. Select the failed array and identify the Channel and ID of the failed drive.
5. Power off and physically remove the failed drive.
6. Replace the drive with an identical model.
7. Reboot the system and enter the FastBuild Main Menu.
8. Select the <5> Rebuild Array option. The following screen will appear.
FastBuild (tm) Utility 1.32 (c) 1996-2001 Promise Technology, Inc.
[ Rebuild Array Menu ]
Array No RAID Mode
Total Drv Capacity(MB) Status
Array 1
Mirror 2
16126 Critical
Array 2
—— —— —— ——
Array 3
—— —— —— ——
Array 4
—— —— —— ——
[ Keys Available ]
[
↑
] Up [
↓
] Down [ESC] Exit [Enter] Selectt
9. Highlight the array whose Status is “Critical”.
10. Press [Enter]. The following screen will then appear (see next page).
The previous recovery is not complete!
<Press Any Key to Restart The Recovery>
Содержание GA-7DX+
Страница 8: ......
Страница 126: ...Appendix 116 5 6 7 8 9 5 Click Next 8 Click Finish to restart computer 6 Click here 7 Click Next ...
Страница 128: ...Appendix 118 7 8 7 Click Finish to restart computer ...