Using FastBuild™ Configuration Utility
The FastBuildTM Configuration Utility offers several menu choices to create and manage the
drive array on the motherboard. For purposes of this manual, it is assumed you have already
created an array in the previous chapter and now wish to make a change to the array or view
other options.
Viewing BIOS Screen
When you boot your system with the RAID function and drives installed, the FastBuild BIOS will
detect the drives attached and show the following screen.
MBFastTrak133 Lite (tm) BIOS Version 2.00.0.XX
(c) 1995-2001 Promise Technology, Inc. All Rights Reserved.
Scanning IDE drives . . . . .
If an array exists already, the BIOS will display the following screen showing the BIOS version
and status of the array.
MBFastTrak133 Lite (tm) BIOS Version 2.00.0.xx
(c) 1995-2001 Promise Technology, Inc. All Rights Reserved.
ID MODE
SIZE TRACK-MAPPING STATUS
1 * 2+0 Stripe
16126M
611/128/32 Functional
Press <Ctrl-F> to enter FastBuild (tm) Utility....
The array status consists of three possible conditions: Functional, Critical, Offline.
Functional - The array is operational.
Critical - A mirrored array contains a drive that has failed or disconnected. The remaining drive
member in the array is functional. However, the array has temporarily lost its ability to provide
fault tolerance. The user should identify the failed drive through the FastBuild
Setup utility,
and then replace the problem drive.
Offline - A striped array has 1 drive that has failed or been disconnected. When the array
condition is “offline,” the user must replace the failed drive(s), then restore data from a backup