TECHNICAL SPECIFICATIONS

PRELIMINARY WARNINGS

Check that the door structure is in conformity with the regulations in force and that door movement is linear without 
friction.

Preliminary checks:

Ÿ

Check that the door structure is sufficiently strong. In any case check that the weight and dimensions of the door fall 

within the limits of use of the operator. 

Ÿ

Check that the door can be moved manually without force (points of greatest friction) for the entire travel of the 
door during both opening and closing.

Ÿ

A garage door is deemed to be well balanced and aligned if it:

§

requires an equivalent amount of applied force to either manually open or close.

§

requires no more than 150N (15Kg) of applied force to either manually open or close.

§

does not rise or fall more than 100mm when released at any point between fully open and fully closed 

positions.

§

does not rub on any supporting or surrounding structures.

Ÿ

If the door is not a new installation, check the state of wear of all the components, repair or replace the defective or 
worn parts and perform any other operations necessary.

Ÿ

Remove or make non-operating the existing locks.

Ÿ

The wall bracket carries all of the opening and closing thrust of the opener and as such must be securily fastened   
to a rigid, structural member of the garage wall or ceiling.

The reliability and safety of the automated device are directy influenced by the status of door structure.

A = Opening time
C = Closing time
P = Overall pause time
A+C+P = Time between two  
                openings

Motor supply voltage

Radio receiver

On board, 100 transmitters max

Speed

Adjustable 90-125 mm/s

Slow downs

Automatic

Supply voltage 

Max force

Operating temperature
Degree of protection

Operating frequency (%)

Operator

Type

TAIMEN T6

TAIMEN T12

Irreversible electromechanical gearmotor

220/230V 50-60 Hz

24Vdc

600 N

-20°C + 60°C

IP 20

30% (at 20°C)

1200 N

-20°C + 60°C

IP 20

30% (at 20°C)

%Fu =

x 100

A + C

A + C + P

Formula to calculate the 

operating frequency

Max door surface

10 sqm

15 sqm

Power absorbed

 

MAX 80W

MAX 110W

Max door height

2,500 mm

2,500 mm

POSITION AND ASSEMBLY CONTROL UNIT-COURTESY LIGHT

DRIVE RAIL ASSEMBLY

WALL BRACKET INSTALLATION

BRACKET INSTALLATION ON THE DOOR

FIXING THE OPERATOR TO WALL BRACKET

Control unit-courtesy light can be installed in three different ways (Fig. 1) .

Ÿ

method A : at the end of the steel drive rail directly on the unit of motor pretensioning and power supply 

Ÿ
Ÿ

 (Fig. 1-A 

and Fig.2).
method B: on the ceiling near the unit of motor pretensioning and power supply (Fig. 1-B).
method C: using the cable extension kit, everywhere (Fig. 1-C).

Ÿ

Compose the drive rail joining the three segments 

 by the two joints 

Ÿ
Ÿ
Ÿ
Ÿ

(Fig. 3-2)

(Fig. 3-1), being sure that the drive rail 

segments are completely put in the junctions.

Put in the assembled drive rail the swinging brackets support  (Fig. 3-3) including roundhead screws and nuts.
Put the pretensioning units at the beginning and at the end of the assembled drive rail (Fig. 3-4) and (Fig. 3-6).
Fix the chain to the pretensioners using the included pins  ( Fig. 3-5).
Use a 13mm socket wrench to adjust the pretensioning screw until the lower part of the screw head aligns with the 

indicator on the pretensioning device ( Fig. 3-7).

Ÿ

Determine the highest point of the door during the movement and mark the level on the wall above the door                         

.

Ÿ

Determine the door center line and mark a vertical line on the wall above the door 

Ÿ

Ÿ
Ÿ

( Fig. 4-1)

( Fig. 4-2).

Position the wall bracket  ( Fig. 4-3) and ensure that the distance between the bracket base and the line previously 

marked is not more than 50mm ( Fig. 4-1).

Mark on the wall the position of the two outer screws holes.
Fix the bracket to the wall ( Fig. 4-4).

Ÿ

Fix the handling bracket to a structural part of the door, using the two self-drilling screws 6mm x 50mm. Be sure that 

the bracket is on the centre and on the top of the door 

.

( Fig. 4-5)

Important Note: in order to avoid any damage to the operator, it is necessary to put the control unit - courtesy 
light on a carton or some protective material 

 .

Ÿ

Be sure that the door is closed 

.

Ÿ

Put the assembled 

 in line with the centre of the door and the control unit-courtesy light far 

from the door 

.

Ÿ

Lift the operator on the side of pretensioning unit 

 till the wall bracket 

Ÿ

Fasten the pretensioning unit to the wall bracket using the long pin and a spring clip. 

( Fig. 5-2)

( Fig. 5-1)

operator on the ground

( Fig. 5-2)

( Fig. 5-4)

( Fig. 5-4).

Содержание TAIMEN T12

Страница 1: ...IT UK TAIMEN T6 T12 Motoriduttori elettromeccanici ISTRUZIONI PER L INSTALLAZIONE Electromechanical gearmotors INSTRUCTIONS FOR INSTALLATION...

Страница 2: ...2 TAIMEN 2 3 1 1 2...

Страница 3: ...50mm 2 1 3 4 5 3 TAIMEN 4 1 2 3 4 5 5 6 7 3...

Страница 4: ...4 TAIMEN 2 600mm 50mm 1 3 4 1 3 4 2 5 6...

Страница 5: ...5 TAIMEN 1 2 3 4 1 2 3 7a 8 7...

Страница 6: ...6 TAIMEN 9 10 1 2 3 OPEN CLOSE Collegamento sensore porta pedonale Pedestrian Door Sensor connection Learn Con rm 11 Accesso alla centrale di comando Central board control unit access...

Страница 7: ...7 TAIMEN 13 12 Collegamento NO NO Connection Disposizione morsetti Terminals layout 1 2 3 4 5 NO 24V COM SB RS NO NO 24V COM SB RS LAMP GND ANT FUSE 10A...

Страница 8: ...3 4 M2 1 MENU 5b on oc 1 2 3 4 5 NO 24V COM SB RS 8K2 8K2 MENU r5 5E 1 2 3 4 5 NO 24V COM SB RS MENU r5 5T 8K2 NC 14 Collegamento FOTOCELLULE PHOTOCELLS connection 15 16 Collegamento COSTA EDGE connec...

Страница 9: ...MEN 17 Collegamento LAMPEGGIANTE FLASHING LIGHT connection 18 Collegamento RICEVENTE ESTERNA EXTERNAL RECEIVER connection LAMP 24Vac MAX 10W SW3 SW1 SW2 LD1 JP4 JP2 A B 1 2 3 4 5 NO 24V COM SB RS DRS...

Страница 10: ...one abilitate all installazione di apparecchi sotto tensione pertanto si richiede una buona conoscenza della tecnica esercitata come professione e nel rispetto delle norme vigenti Lamanutenzionedevees...

Страница 11: ...one o nelle immediate vicinanze dell automazione stessa I bambini vanno supervisionati costantemente quando sono nelle vicinanze della porta e quandoquesta infunzione Sbloccarel operatoresoloaportacom...

Страница 12: ...hepreliminari Controllare che la struttura della porta sia sufficientemente robusta in ogni caso verificare che la porta abbia pesoedimensionicherientranoneilimitidiimpiegodell operatore Controllare c...

Страница 13: ...che la parte inferiore dellatestadellavite incorrispondenzadell indicatoresuldispositivodipretensionamento Fig 3 7 Determinare il punto pi alto raggiunto dalla porta durante il movimento e tracciare l...

Страница 14: ...ilizzareidueforipi distantieunaspinaamolla Fig 7a 3 CONNESSIONE ALLA RETE ELETTRICA Connettere l operatore alla rete elettrica che deve essere dotata di opportuno sistema di messaaterra Assicurarsi ch...

Страница 15: ...corsa In questa rl Modalit apprendimento radiocomandi fr Factory reset FUNZIONE TASTI A BORDO Con rm Learn Learn In pausa Nel menu Brevepressione apprendimento cancellazionetrasmettitori Tenutopremuto...

Страница 16: ...avvenutacancellazione RilasciareiltastoLEARN Assegnazionespecifichefunzioniaitastidelradiocomando E possibileassegnarediversefunzioniaitastidelradiocomandoconl impostazionedelparametrotr APPRENDIMENTO...

Страница 17: ...NFIRM la selezione lampegger velocemente e il displaytorner avisualizzareilparametroappenamodificato Se non si vuole salvare la modifica effettuata premere LEARN per andare al menu precedente e non sa...

Страница 18: ...omandi Funzionamentoseattivatoduranteilmovimentodiapertura bloccailmotoelacentralerestainattesadicomandi RSabilitatocomestop8K2 installareildispositivo 18 TAIMEN IT PARAMETRI Descrizione Stato Funzion...

Страница 19: ...apertura STOP Portaaperta CHIUDE Durantelachiusura INVERTEILMOTO NO au Ingresso abilitatocomestartconlogicaAUTOMATICA FunzionamentoinrispostaalcomandodiSTART Portachiusa APRE Durantel apertura ININFLU...

Страница 20: ...na la luce di cortesia Li Tasto abilitato come comando di ventilazione La porta chiude e riapre per il 20 dellacorsa sirichiuder trascorsi30minuti Ve Nessunafunzioneassegnata Tastoabilitatocomecomando...

Страница 21: ...Learn Con rm Learn Con rm Learn Con rm Learn AC 0F 30 90 CHIUSURA RAPIDA FC Disabilitalafunzionechiusurarapida In seguito all intercettazione e alla successiva liberazione delle fotocellule verr rica...

Страница 22: ...Illampeggiantesicomportaesattamentecomelalucedicortesia CL fl bl cl Con rm Learn Con rm Learn Con rm Learn Con rm Learn Con rm Learn La modifica di questo parametro comporta la necessit di eseguire un...

Страница 23: ...manovradiantischiacciamento Funzionamento Non attivo nella parte terminale del moto in prossimit delle battute di chiusuraeapertura Il suo intervento in chiusura determina l inversione immediata del...

Страница 24: ...ueperinteroiltempodimarciaveloceepoiiltempodirallentamento Configurazioneconsigliataperantegrandi pesanti Recuperotempiattivo La centrale esegue calcoli nel tentativo di eseguire correttamente la fase...

Страница 25: ...forzatodiapertura Tenendopremutoiltasto per8secondiemantenedolopremutolaportasimuover lentamenteinapertura Alrilasciodeltasto laportasifermer Movimentoforzatodichiusura Tenendopremutoiltasto per8secon...

Страница 26: ...ta si sta chiudendo LUCE LAMP LAMP LAMP CORTESIA LAMP CORTESIA LAMP CORTESIA LAMP CORTESIA LAMP CORTESIA Procedura apprendimento corsa 2s ON 2s OFF Al comando di start esegue ciclo di apprendimento LA...

Страница 27: ...le seguenti norme armonizzate Data 01 10 2018 S r l OPERATORI ELETTROMECCANICI TAIMEN T6 T12 DirettivaLVD2006 95 CE esuccessivemodifiche DirettivaEMC2004 108 CEesuccessivemodifiche EN60335 1 EN61000 6...

Страница 28: ...heck proper functioning of the system and the devicesused This instruction manual addresses persons qualified for installation of live equipment therefore good technicalknowledgeisrequiredexercisedasp...

Страница 29: ...nder or near the path of the garage door Children must be supervisedatalltimeswhennearthegaragedoorandwhentheopenerisinuse Alwaysdisengagetheopenerwiththegaragedoorinthefullyclosedposition Before atte...

Страница 30: ...tanewinstallation checkthestateofwearofallthecomponents repairorreplacethedefectiveor wornpartsandperformanyotheroperationsnecessary Removeormakenon operatingtheexistinglocks The wall bracket carries...

Страница 31: ...ioning screw until the lower part of the screw head aligns with the indicatoronthepretensioningdevice Fig 3 7 Determine the highest point of the door during the movement and mark the level on the wall...

Страница 32: ...8 included taking care ofusingthetwomoredistantholesandaspringclip Fig 7a 3 CONNECTION TO POWER SUPPLY Connect usingtheprovided theoperatortotheproperlyearthedpowersupply Besurethatthepowercabledoesno...

Страница 33: ...use In the menu Shortpressure Pushedfor8s Readthechapter FORCEDMOVEMENTOFTHEDOOR Slidethemenuortheavailableselections In pause Shortpressure Accesstothemenu Photocell interrupted e2 Safety edge stop i...

Страница 34: ...nhasbeencompleted ReleasetheLEARNbutton Assigningspecificalfunctionstotransmitterbuttons Itispossibletoassigndifferentfunctionstothetransmitterbuttonsbysettingtr parameter TRAVEL LEARNING AND ANTI CRU...

Страница 35: ...selection will blink fast and the parameterjustmodifiedwillappearagainonthedisplay If you do not want to save the modification done push LEARN to return to previous menu and do not save the modificati...

Страница 36: ...rn 0F 0n Con rm Learn OC Con rm Learn Display Con rm Learn 5b 5b TerminalRS disabled terminal5 RS TERMINAL FUNCTION 0F 5e Terminal terminal5 Operationduringclosingmovement reverse the motion for 2s wh...

Страница 37: ...Duringopening STOP Dooropen CLOSE Duringclosing REVERSETHEMOTION NOen au InputNOenabledasstartwithAUTOMATIClogic Operation Doorclosed OPENS Duringopening IRRELEVANT Door open Restarts the pause time...

Страница 38: ...sing ru Button automaticallyagain enabled as opening command the door opens and does not close rc op Buttonenabledasstartstep by stepwithstoponlyinopening Transmitterbutton1 DEFAULTru b1 Transmitterbu...

Страница 39: ...arn Con rm Learn AC 0F 30 90 FAST CLOSING The fast closing function is disabled After the interception and subsequently releaseofthephotocells thepausetimewillbechargedagain 0F FC Thefastclosing abled...

Страница 40: ...xedflashinglight terminalLAMP Theflashinglightbehavesexactlyasthecourtesylight CL fl bl cl Con rm Learn Con rm Learn Con rm Learn Con rm Learn Con rm Learn The modification of this parameter implies t...

Страница 41: ...emakingthe anti crushingmanoeuvre Operation Itisdisabledinthelastpartofthemotion nearopeningandclosingstops Its intervention in closing causes the immediate inversion of the motion decelerating till a...

Страница 42: ...olefastworkingtimeandthentheslowdowntime Configurationsuggestedforbig heavydoors Timerecoveryenabled The control unit makes some calculation attempting to correctly make the slow down phase before the...

Страница 43: ...ead door it is necessary to use the curved arm provided separately FORCED MOVEMENT OF THE DOOR Atanytime whenthemotorhasstopped itispossibletoforceanopeningorclosingmanoeuvre WARNING Duringtheforcedmo...

Страница 44: ...g command the door opens Door blocked and closed Door blocked and open Door blocked Door blocked and open The door is opening The door is closing Atravellearningcycle beginsat astartcommand Entering m...

Страница 45: ...12 o the following CEE Directives and that the following harmonised standards have been applied LVDDirective2006 95 CE andsubsequentamendments EMCDirective2004 108 CEandsubsequentamendments EN60335 1...

Страница 46: ...46 NOTE NOTES TAIMEN...

Страница 47: ...47 NOTE NOTES TAIMEN...

Страница 48: ...DI S r l Via Abetone Brennero 177 B 46025 Poggio Rusco MN ITALY Tel 39 0386 52 20 11 Fax 39 0386 52 20 31 E mail info gibidi com Numero Verde 800 290156 w w w g i b i d i c o m Cod AIC1023 08 2020 Re...

Отзывы: