I
UK
UK
INSTALLATION WARNINGS
CAUTION: IMPORTANT SAFETY INSTRUCTIONS
It is important to follow these instructions in order to safeguard persons.
Keep this instruction booklet.
GROUND allows practically invisible automation of swing gates
The automated device consists of an electromechanical underground operator in both 24 VDC and 230 VAC version,
able to transmit motion to leafs of up to 3.5 m
.
.
•
.
•
.
•
.
•
.
•
.
•
.
•
.
•
.
•
.
•
.
•
.
•
.
•
.
•
.
•
.
•
.
•
.
Before proceeding with installation, fit a magnetothermal or differential switch with a maximum capacity of 10A
upstream of the system. The switch must guarantee omnipolar separation of the contacts with an opening distance
of at least 3mm
Keep all the materials contained in the packaging away from children, since they pose a potential risk
The manufacturer declines all responsibility for improper functioning of the automated device if the original
components and accessories suitable for the specific application are not used
After installation, always carefully check proper functioning of the system and the devices used
This instruction manual addresses persons qualified for installation of “live equipment”. Therefore, good technical
knowledge and professional practice in compliance with the regulations in force are required
Maintenance must be carried out by qualified personnel
Before carrying out any cleaning or maintenance operation, disconnect the control unit from the mains
This product has been designed and constructed exclusively for the use indicated in this documentation. Any other
use may cause damage to the product and be a source of danger
Check the intended end use and take all the necessary safety precautions
Use of the product for purposes different from the intended use has not been tested by the manufacturer, therefore
any work is carried out on full responsibility of the installer
Mark the automated device with visible warning plates
Warn the user that children or animals should not play or stand near the gate
Appropriately protect the danger points (for example, using a sensitive frame)
Check that the earthing system has been properly constructed: connect all the metal parts of doors, gates, etc. a n d
all the system components to an earth terminal
Exclusively use original spare parts for any maintenance or repair operations
Do not modify any components of the automated device unless expressly authorised by Gi.Bi.Di
Use suitable cable clamps to assure proper mechanical connection of the wiring and such as to maintain the IP
degree of protection
INTRODUCTION
GROUND
18
Содержание GROUND 610
Страница 3: ...GROUND 3 2a 3 4 2b PULL 60 mm 180 mm 436 mm 353 mm 414 mm 343 mm 72 mm 72 mm 180 mm 180 mm 72 mm 60 mm...
Страница 4: ...GROUND 4 9 7 8 6 5 72 mm 35 mm 200 mm 400 mm 500 mm 6 5 3 4 2 1...
Страница 5: ...GROUND 11 13 14 10 12 min 10 mm C 250 mm min 40 mm C PULL 5...
Страница 8: ...GROUND 8 20 21...
Страница 9: ...6 5 3 4 7 3 5 1 2 4 7 4 3 6 5 1 2 GROUND 22 24 25 23 9...
Страница 43: ...GROUND 43 NL...
Страница 50: ...GROUND 50 NOTE NOTES...
Страница 51: ...GROUND 51 NOTE NOTES...