PROFESSIONAL AUTOMATIC SYSTEM FOR GATES AND GARAGEDOORS
English
7
Power supply
230 VAC, single-phase, 50 /60 Hz
No. of motors
2 x 12 VDC 30W (code AS04330 )
2 x 12 VDC 60W (code AS04340)
Flashlight
12 VDC 15W max.
Photocell power supply
12 VDC 6W max. (2 pairs of photocells)
Electric lock
12 VDC 15W max.
Operating temperature
-20 to +60°C
Pause Time
0 - 240 s
Run time
0 - 240 s
Fixed pre-flashing
2 s
The electronic control unit code AS04330 and AS04340 for control of one or two 12 VDC motors for swing gates is in conformity with the Directives
in force.
Functions available: - step-by-step
- step-by-step with automatic reclosing (residential)
- condominium
- pedestrian opening with second remote control channel (only with RADIO MODULE code AU01780)
- water hammer
- deceleration
- automatic closing after freeing the photocells
Adjustments :
- run time
- pause time
- gate phase shift time
- amperometric thresholds
General
Connections (Terminal Board Legend)
TECHNICAL CHARACTERISTICS
1
PHOTOCELL input (NC)
11 - 12
Output Motor 2 ( 12 positive during opening )
2
STOP input (NC). Causes a functional stop of the
motion (NOT A SAFETY STOP)
13 - 14
Output Motor 1 (= it opens for first) to be used for
pedestrian gate (14 positive during opening)
3
START input (NO)
15
ANTENNA ground
4
COMMON for STOP-START-PHOTOCELLS
16
ANTENNA signal
CN2-
CN3
12 VAC input (from transformer)
CN4 -
CN5
(
*
)
Input for 12 VDC BUFFER BATTERY (CN4 = positive)
F - N
Power supply, 230 VAC, single-phase, 50/60 Hz
7 - 8
12 VDC output for ELECTRIC LOCK power supply
(max. 15 W)
5 - 6
12 VDC output for power supply, max. 2 pairs of
photocells (6 = POSITIVE)
9 - 10
12 VDC output for FLASHLIGHT ( max. 15 W )
A)
Before proceeding with installation, fit a magnetothermal or differential switch with maximum capacity of 10A upstream of the system.
The switch must guarantee omnipolar separation of the contacts with an opening distance of at least 3 mm.
B)
To prevent possible inter ference, differentiate and always keep the power cables (minimum cross-section 1.5 mm
2
) separate from the
signal cables which must be at least 0.5 mm
2
.
C)
Make the connections referring to the following table and the attached silk-screen print. Be ver y careful to connect in series all the
devices that are connected to the same NC (normally closed) input and in parallel all the devices that share the same NO (normally open)
input.
Incorrect installation and improper use of the product may compromise the safety of the system.
D)
All the material contained in the package must be kept out of reach of children, since they constitute a potential hazard.
E)
The manufacturer declines all responsibility for proper functioning of the automated device if original Gi-Bi-Di components and accessories
suitable for the application are not used.
F)
After installation always carefully check proper functioning of the system and the devices used.
WARNINGS
(
*
) WARNING:
IF USING WITH BATTERY, THE “OPTIONAL CABLE” ACCESSORY SPECIFICALLY DESIGNED FOR RECHARGING IS REQUIRED.
CONNECTING A BATTERY WITHOUT THIS SPECIAL CABLE MAY CAUSE IRREPARABLE DAMAGE TO THE CONTROL UNIT.
Содержание F12E
Страница 2: ...Italiano 2 AUTOMATISMI PROFESSIONALI PER CANCELLI E GARAGE...
Страница 31: ...31...