19
DPT260
7 - CONTROL UNIT
7.1 - MASTER AND SLAVE CIRCUIT
7.2 - PROTECTION FUSES MASTER - SLAVE
7.3 - MASTER PUSH BUTTONS
Button
RESET
START
PROG
Function
Resets the program (in case of crash)
Operates a rising and lowering control or a lowering control depending on dip switch 1 settings
Allows to modify some setting parameters of the system (230V +/-10% per each moving bollard)
Master
Slave
F1
F2
F3
F5
F1
F6
F7
F2
Typology
Protection
2A delayed
Protection transformer 230V - 24 VAC supply
1A delayed
Protection timer programming supply
2A delayed
Protection traffic lights supply
5A delayed
Protection optional accessories supply (terminals 1-2-3 / 31-32-33
1A delayed
2A delayed
Protection safety devices supply
Logic protection
F5 5AT
F3 2AT
PIL16 MASTER CIRCUIT
PIL16 SLAVE CIRCUIT
F2 1AT
F7 2AT
F1 2AT
F6 1AT
F1 5AT
F2 2AT
PIC. 21
UK