Installation of the Giant Industries, Inc., pump
is not a complicated procedure, but there are
some basic steps common to all pumps. The
following information is to be considered as a
general outline for installation. If you have
unique requirements, please contact Giant
Industries, Inc. or your local distributor for
assistance.
1. The pump should be installed flat on a base to
a maximum of a 15 degree angle of inclination to
ensure optimum lubrication.
2. The inlet to the pump should be sized for the
flow rate of the pump with no unnecessary
restrictions that can cause cavitation. Teflon tape
should be used to seal all joints. If pumps are to
be operated at temperatures in excess of 160
0
F,
it is important to insure a positive head to the
pump to prevent cavitation.
3. The discharge plumbing from the pump should
be properly sized to the flow rate to prevent line
pressure loss to the work area. It is essential to
provide a safety bypass valve between the pump
and the work area to protect the pump from
pressure spikes in the event of a blockage or the
use of a shut-off gun.
4. Use of a dampener is necessary to minimize
pulsation at drive elements, plumbing, connec-
tions, and other system areas. The use of a
dampener with Giant Industries, Inc. pumps is
optional, although recommended by Giant
Industries, Inc. to further reduce system pulsa-
tion. Dampeners can also reduce the severity of
pressure spikes that occur in systems using a
shut-off gun. A dampener must be positioned
downstream from the unloader.
5. Crankshaft rotation on Giant Industries, Inc.
pumps should be made in the direction desig-
nated by the arrows on the pump crankcase.
Reverse rotation may be safely achieved by
following a few guidelines available upon request
from Giant Industries, Inc. Required horsepower
for system operation can be obtained from the
charts on page 3.
6. Before beginning operation of your pumping
system, remember: Check that the crankcase
and seal areas have been properly lubricated per
recommended schedules. Do not run the pump
dry for extended periods of time. Cavitation will
result in severe damage. Always remember to
check that all plumbing valves are open and that
pumped media can flow freely to the inlet of the
pump.
Finally, remember that high pressure operation in a pump system has many advantages. But, if it is used
carelessly and without regard to its potential hazard, it can cause serious injury.
IMPORTANT OPERATING CONDITIONS
Failure to comply with any of these conditions invalidates the warranty.
1. Prior to initial operation, add oil to the crank-
case so that oil level is between the two lines on
the oil dipstick. DO NOT OVERFILL.
Use SAE 80-90W or Giant’s p/n 01154
Crankcase oil should be changed after the
first 50 hours of operation, then at regular inter-
vals of 500 hours or less depending on operating
conditions.
2. Pump operation must not exceed rated
pressure, volume, or RPM. A pressure relief
device must be installed in the discharge of the
system.
3. Acids, alkalines, or abrasive fluids cannot be
pumped unless approval in writing is obtained
before operation from Giant Industries, Inc.
4. Run the pump dry approximately 10 seconds
to drain the water before exposure to freezing
temperatures.
INSTALLATION INSTRUCTIONS