Connectors and hoses
Hoses and unions do not require any maintenance operation.
Check the tightness of the unions where oil leaks occur.
ENGINE
ANY OPERATION WITH THE ENGINE WORKING IS RESERVED TO SPECIFIC PERSONNEL
AND IT REQUIRES THE DISCONNECTION OF A SAFETY DEVICE THAT MUST BE ALWAYS
RESTORED.
DO NOT MODIFY THE SETTING OF THE SPEED REGULATOR.
ALWAYS REPLACE THE DAMAGED MUFFLERS.
To correctly use and check the engine, operators are strongly advised to thoroughly read the instructions give in
the Use and Maintenance Manual for the specific engine in question.
Cleaning the engine radiator and hydraulic oil
We recommended to clean with care the radiator with compressed air. If coolant temperature is > 100° or the
max. temperature acoustic buzzer
sounds, immediately stop working, let the engine run at low speed for a few seconds before turning it off and
immediately clean the net and the
radiator itself.
Air precleaner maintenance
Air filter is protected by a self-cleaning precleaner located above the same
filter.
The precleaner shall be cleaned at least once a year. Procedure: remove the
fixing screw placed of the cover, remove the cover and check that the fan
turns freely.
Air filter
Positioned in the rear right part
of the machine (Turboloader M
and S) above the battery. We
recommended the replacement
each 200 hours of work. For the
substitution of it, take out the
upper cover, unscrew the cap
that close the filter box and
extract the cartridge.