www.ghibliwirbel.com
Professional Cleaning Machines Since 1968
EN
- 21
TROUBLESHOOTING
PROBLEM
CAUSE
SOLUTION
The machine does not start
up when the key is turned.
Low battery.
Main fuse blown.
Defective key.
Check that the battery is
charged.
Replace the fuse found on
the battery cable.
Change the key.
The brush doesn’t turn.
Movement set to neutral.
Engine trouble.
Faulty board.
Engage forward or reverse
movement.
Replace engine.
Change the board.
The suction unit does not
function.
Recovery tank full.
Defective turbine motor.
Faulty board.
Empty the tank.
Change the motor.
Change the board.
The machine does dry prop-
erly, leaving traces of water
on the floor.
Aspirator off.
Aspiration tube blocked.
Recovery tank full.
Squeegee rubber blades
worn.
Start up the aspirator.
Check and if necessary
clean the aspiration tube that
connects the squeegee to
the recovery tank.
Empty the recovery tank.
Replace or turn over the
squeegee rubber blades.
No water comes out.
Tank empty.
Defective water pump.
Faulty board.
Filter clogged.
Pump solenoid valve not
functioning.
Fill the tank.
Change the water pump.
Change the board.
Clean the filter.
Call technical assistance.