7. Initial operation 

 

The MLR is ready to be operated in a few simple steps. Depending on the type of 
use you can adjust the desired position electrically in a very short period of time. 
The power cable has to be connected to the socket directly. Do not lead the power 

cable through the round opening of the lower wooden panel. 
 

8. Manual Control Panel 

 

 

For  safety  reasons,  the  MLR  moves  only  while  pressing  a  key  of  the 

MCP.  When  you  stop  pressing,  all  moving-operation  will  stop 
immediately. 

 

1 Head/back section 

 

2 Leg/foot section 

3 Height 

4 Inclination/Trendelenburg 

 

8.1 Head/back section 

 
You  can  adjust  the  inclination  of  the  head/back  section  electrically  so  the 

inclination can be adapted relevant to the needs of the application you would like 
to carry out. 

The upholstery of the headrest has an opening for the nose usable when carrying 
out back-massages (fig. 1). The cover plug of the opening is removable. Using a gel 

Содержание MLR

Страница 1: ...MANUAL Spa Table Gharieni MLR Gharieni Group GmbH Gutenbergstra e 40 D 47443 Moers Phone 49 0 2841 88300 0 Fax 49 0 2841 88300 999 E mail service gharieni de Web www gharieni de Service Hotline 49 0 2...

Страница 2: ...k section 6 8 2 Leg foot section 7 8 3 Height of the MLR 7 8 4 Inclination Trendelenburg Anti Trendelenburg 7 9 Heater Smart Thermo 8 9 1 Heater control panel 8 9 2 Heating 8 9 3 Manufacturers setting...

Страница 3: ...place so you can use it whenever it is needed Strictly observe the instructions to avoid damage to persons and property DANGER 1 All electrical work to connect the MLR to the mains must be carried ou...

Страница 4: ...unpacking the packaging materials polythene bags polystyrene pieces etc should be kept away from children CHOKING HAZARD 13 Always keep children away from the MLR 14 Children must not play with the ML...

Страница 5: ...company the MLR is delivered on a special pallet packaged in cardboard boxes The MLR is in complete horizontal position and the upholstery is installed Open the top of the cardboard box carefully Do...

Страница 6: ...y reasons the MLR moves only while pressing a key of the MCP When you stop pressing all moving operation will stop immediately 1 Head back section 2 Leg foot section 3 Height 4 Inclination Trendelenbu...

Страница 7: ...nation covers the complete thigh area the knee and the feet 8 3 Height of the MLR The height of the lying surface can be adjusted from 57 cm to 97 cm 8 4 Inclination Trendelenburg Anti Trendelenburg T...

Страница 8: ...r high temperatures WARNING 1 Do not use the option Smart Thermo when your customer has got a pacemaker is pregnant is affected by thrombosis suffers from pain due to unknown reasons Apply to healthy...

Страница 9: ...he following combination to enter the programming mode 1 Press and hold the OFF button 2 Press and release the ON button 3 Release the OFF button and enter the Setting of the total operation period Yo...

Страница 10: ...e heater is complete You can finish the programming of the heater by pressing the OFF button at any point of time 10 Cleaning 1 Clean the housing using a damp cloth or sponge and a small amount of soa...

Страница 11: ...ons corresponding to German VDE 0100 or 0107 at the site where the MLR is operated 3 The MLR is operated as described in the instruction manual Unauthorized modifications or manipulating the MLR will...

Страница 12: ...ice gharieni de Service Hotline 02841 88300 40 14 Malfunctions Malfunction Possible causes Fault recovery All motors do not work 1 No energy supply 2 Key lock is activated 3 Defective power cable 4 MC...

Страница 13: ...es incl controls Power of transformer primary 230 V AC 50 Hz Power of transformer secondary 24 V DC Protection 3 ampere AT Duty cycle drive 10 max 2 minutes of permanent operation 18 minutes rest MCP...

Страница 14: ...MLR Spa Table Type or model name is produced in accordance with the requirements specified in Low Voltage Directive LVD 2006 95 EG Electromagnetic Compatibility 2004 108 EG Safety of Machinery 2006 42...

Страница 15: ...ARE RESERVED ITS REPRODUCTION OR TRANSMISSION TO THIRD PARTIES IS FORBIDDEN WITHOUT THE AUTHORISATION OF THE OWNING COMPANY THE POWER TO PROTECT ITS RIGHTS IS RESERVED AND OFFENDERS SHALL BE PROSECUT...

Отзывы: