  Setting of the pre-heating period 

 

Each  illuminated  LED  indicates  a  pre-heating  period  of  3  minutes.  The 
manufacturer´s  setting  is  6  minutes.  The  max.  pre-heating  period  available  is  30 
minutes. Do not exceed the default values set by the manufacturer. 

While  the  heater  is  still  warm,  the  pre-heating  period  may  be  shorter  when  the 
heater is switched on again. 
 

Press the ON-button to save your setting, then you enter the 
 

  Setting of the power during treatment 

 
The currently-saved value is indicated by one LED bar. The number of illuminated 

LEDs indicates the set heating power in 10% steps. Manufacturer`s setting is 30%. 
Set the desired value by pressing the 

+

 and 

-

 buttons. Save your setting by pressing 

the ON-button. 

 

The programming of the heater is complete. 

 

 

You  can  finish  the  programming  of  the  heater  by  pressing  the  OFF-
button at any point of time. 

 

10 Cleaning 

 
1.

 

Clean the housing using a damp cloth or sponge and a small amount of soap 
only. 

2.

 

The standard upholstery surface of the MLR is made of synthetic leather or PU 
(polyurethane). We recommend the use of suitable protective covers to keep the 
lying surface in good condition. 

 

Protective covers available at Gharieni Group GmbH 

 

Standard cosmetic applications. 

5-parts terry cloth.. 

Messages  including  a  small  amount  of 

oil. 

Require  the  MLW-protective  cover 

made of PU. It protects the upholstery 
from stains of oil and seeping in of oil. 

Ayurveda applications with oil pouring.  Require  the  special  protective  cover 

including an integrated edge. Only when 
using this protective cover, the structure 

and  the  electric  components  of  the 
MLR are protected. 

 

3.

 

Disconnect the MLR from the mains before you clean the upholstery. 

Содержание MLR

Страница 1: ...MANUAL Spa Table Gharieni MLR Gharieni Group GmbH Gutenbergstra e 40 D 47443 Moers Phone 49 0 2841 88300 0 Fax 49 0 2841 88300 999 E mail service gharieni de Web www gharieni de Service Hotline 49 0 2...

Страница 2: ...k section 6 8 2 Leg foot section 7 8 3 Height of the MLR 7 8 4 Inclination Trendelenburg Anti Trendelenburg 7 9 Heater Smart Thermo 8 9 1 Heater control panel 8 9 2 Heating 8 9 3 Manufacturers setting...

Страница 3: ...place so you can use it whenever it is needed Strictly observe the instructions to avoid damage to persons and property DANGER 1 All electrical work to connect the MLR to the mains must be carried ou...

Страница 4: ...unpacking the packaging materials polythene bags polystyrene pieces etc should be kept away from children CHOKING HAZARD 13 Always keep children away from the MLR 14 Children must not play with the ML...

Страница 5: ...company the MLR is delivered on a special pallet packaged in cardboard boxes The MLR is in complete horizontal position and the upholstery is installed Open the top of the cardboard box carefully Do...

Страница 6: ...y reasons the MLR moves only while pressing a key of the MCP When you stop pressing all moving operation will stop immediately 1 Head back section 2 Leg foot section 3 Height 4 Inclination Trendelenbu...

Страница 7: ...nation covers the complete thigh area the knee and the feet 8 3 Height of the MLR The height of the lying surface can be adjusted from 57 cm to 97 cm 8 4 Inclination Trendelenburg Anti Trendelenburg T...

Страница 8: ...r high temperatures WARNING 1 Do not use the option Smart Thermo when your customer has got a pacemaker is pregnant is affected by thrombosis suffers from pain due to unknown reasons Apply to healthy...

Страница 9: ...he following combination to enter the programming mode 1 Press and hold the OFF button 2 Press and release the ON button 3 Release the OFF button and enter the Setting of the total operation period Yo...

Страница 10: ...e heater is complete You can finish the programming of the heater by pressing the OFF button at any point of time 10 Cleaning 1 Clean the housing using a damp cloth or sponge and a small amount of soa...

Страница 11: ...ons corresponding to German VDE 0100 or 0107 at the site where the MLR is operated 3 The MLR is operated as described in the instruction manual Unauthorized modifications or manipulating the MLR will...

Страница 12: ...ice gharieni de Service Hotline 02841 88300 40 14 Malfunctions Malfunction Possible causes Fault recovery All motors do not work 1 No energy supply 2 Key lock is activated 3 Defective power cable 4 MC...

Страница 13: ...es incl controls Power of transformer primary 230 V AC 50 Hz Power of transformer secondary 24 V DC Protection 3 ampere AT Duty cycle drive 10 max 2 minutes of permanent operation 18 minutes rest MCP...

Страница 14: ...MLR Spa Table Type or model name is produced in accordance with the requirements specified in Low Voltage Directive LVD 2006 95 EG Electromagnetic Compatibility 2004 108 EG Safety of Machinery 2006 42...

Страница 15: ...ARE RESERVED ITS REPRODUCTION OR TRANSMISSION TO THIRD PARTIES IS FORBIDDEN WITHOUT THE AUTHORISATION OF THE OWNING COMPANY THE POWER TO PROTECT ITS RIGHTS IS RESERVED AND OFFENDERS SHALL BE PROSECUT...

Отзывы: