Part No.: 790 000
GfS Door Teminal
7
790000_Ai_GfS-Door_Terminal_1112_GB
FUNCTIONS
Permanent opening
Permanent opening is active as long as Input “Remote” is activated.
Permanent opening with key switch: Turn key switch clockwise for
at least 5 sec., till LEDs expire. Remove key.
LEDs and emergency exit switch illumination are pulsing.
Door may be opened as long and as often as desired.
Magnets are permanently deactivated.
pulse
green
Waiting for door to be closed
The LEDs blink slowly green
at the end of the opening time.
In case that the holding magnet and door contact are not closed the
LEDs blink green for another 15 sec
(till conditions for activation are met).
blinks slowly
green
Door-too-long-open
If the door stays open for more than 15 sec. an alarm
“Door-too-long-open” is triggered.
Every 3 secs the green LEDs change for 200 ms into red,
while the internal and external buzzers are activated.
Deactivation of alarm
Close door (door reed contact, counter plate) or give again an
opening command (opening command 1 and 2 possible)
Intermitting
red/green LEDs
+ buzzer
Emergency exit switch alarm
Push emergency exit switch
Flash-light, buzzer (internal and external) are activated, deactivation
of incident message relay, magnets are seperated and deactivated
by the processor.
LEDs blink quickly green (as after opening command).
Reset of alarm just possible with key switch. Unlatch emergency
exit switch.
blinks green
+ siren
+ flash light