The GfS Door Terminal is a compact device to steer up to 

2 holding magnets which are mounted on emergency exit 

doors. It includes emergency exit switch, flash light, buzz-

er and key switch. The housing is made out of solid stain-

less steel.

In order to make full use of all GfS Door Terminal features 

and to assure the safety of the operator it is important to 

act according to the following instructions.

Before connecting and operating the device please 
read the operating manual carefully.

•  The eletric installation must be executed by an

  authorized installer

•  Before opening the device the external power supply 

  has to be switched-off

•  In case of system failure please disconect the device 

  and ask an authorized installer to repair it

•  Please use the device just according to the following 

 instruction

    

This assembly instruction should be handed on to 
the operator

INDROTUCTION/SAFETY INSTRUCTION

INSTALLATION 

IMPORTANT:
Connect the GfS Door Terminal completely before 
applying voltage.

•  Mount the GfS Door Terminal on the wall with the

  enclosed screws (see hole pattern). You can find the 

  different measures on page 4)

•  Connect all required cables

•  Tighten the screws of the emergency exit button 

  insertion (positioned horizontally)

•  Tighten the screws of the cover of the LED-field 

  (positioned vertically)

•  Now, apply the voltage

•  Carry out function test

ATTENTION
GfS recommends to checks the functions of the
GfS Door Terminal every 6 months.

Weitergabe oder Vervielfältigung dieser Bedienungsanleitung, Verwer-

tung  und  Mitteilung  ihres  Inhalts  sind  nicht  gestattet,  soweit  nicht 

 

ausdrücklich zugestanden. Zuwiderhandlungen verpflichten zu Schadener-

satz. Alle Rechte für den Fall der Patenterteilung oder Gebrauchsmuster- 

Eintragung vorbehalten.

Die Angaben in dieser Bedienungsanleitung können ohne vorherige  

Ankündigung geändert werden. Die Zusammenstellung der Informationen 

in dieser Bedienungsanleitung erfolgt nach bestem Wissen und Gewis-

sen. GfS – Gesellschaft für Sicherheitstechnik mbH übernimmt keine 

Gewährleistung für die Richtigkeit und Vollständigkeit der gemachten An-

gaben. Insbesondere kann GfS – Gesellschaft für Sicherheitstechnik mbH 

nicht für Folgeschäden aufgrund fehlerhafter oder unvollständiger Anga-

ben haftbar gemacht werden. Da sich Fehler, bei aller Sorgfalt nie vermei-

den lassen, sind wir für Hinweise jederzeit dankbar.

1200

850

Escape direction

Содержание 790 000

Страница 1: ...Assembly Instruction GfS Door Terminal Safety on doors Part No 790 000 P a r t N o...

Страница 2: ...screws see hole pattern You can find the different measures on page 4 Connect all required cables Tighten the screws of the emergency exit button insertion positioned horizontally Tighten the screws...

Страница 3: ...control system with bridge normal operation 1x emergency exit switch with internal fail safe contacts 1x reserve input Output 2x holding magnet electric escape route strikes 1x RS 485 interface bi dir...

Страница 4: ...GfS Door Teminal Part No 790 000 4 790000_Ai_GfS Door_Terminal_1112_GB DIMENSION 240 198 10 72 90 42 20 60 80 80 15 50 41 98...

Страница 5: ...10 and 11 Opening command 12 GND Reference contact for door contact Signal GND 13 DC Contact Switch on GND resp bridge 12 and 13 Door closed 14 RS 485A Communication Data signals 15 RS 485B Communicat...

Страница 6: ...lowly twice and the GfS Door Terminal is activated again Precondition Holding magnet and door contact are closed When the door is opened during the opening time delay and no opening contact active the...

Страница 7: ...her 15 sec till conditions for activation are met blinks slowly green Door too long open If the door stays open for more than 15 sec an alarm Door too long open is triggered Every 3 secs the green LED...

Страница 8: ...in push pull The deactivation of the alarm only with key switch turn right possible blinks green Intrusion sabotage In case that one of the two feedback loops of the holding magnets or door contacts a...

Страница 9: ...ange orange orange 1x 1x 1x Change opening time Execute programming steps 1 3 Orange LED ring shines Programming mode opening time Start programming execute step 5 turn to the right Confirm programmin...

Страница 10: ...m to red silent alarm Execute programming step 7 in order to end the programming orange green on red off 1x 1x 1x store leave programm Automatic accoustic alarm switch off Execute programming step 1 3...

Страница 11: ...light Part No for the flash light of the GfS Door Terminal red 799 000 Replacement cover for emergency exit switch Part No for emergency exit switch of the GfS Door Terminal made out of unbrakeable Ma...

Страница 12: ...GfS Gesellschaft f r Sicherheitstechnik mbH Tempowerkring 15 21079 Hamburg Fon 0 40 79 01 95 0 Fax 0 40 79 01 95 11 info gfs online com www gfs online com Stamp 790000_Ai_GfS Door_Terminal_1112_GB...

Отзывы: