GFS 790 000 Скачать руководство пользователя страница 3

Part No.: 790 000  

 

GfS Door Teminal

 

3

790000_Ai_GfS-Door_Terminal_1112_GB

TECHNICAL DATA

Power supply

 

12V-24V DC

Consumption

 

State of activation 365 mA

   

(1 holding magnet)

   

State of alarm 150 mA

Degree of protection

 

IP 20

Output

  

1 incident message relay

Max. contact load DC

 30V/0,5A

Operating temperature

  -20C bis +60C

Dimensions

  

90 x 240 x 80 mm

Weight

  

ca. 1,6 kg

•  2x 32 LED (red/green) for displaying the actual status

•  integrated buzzer with 100dB/ 1m

•  integrated flash light

•  emergency exit switch acc. to EN60947-5-1

•  integrated key switch

•  2 mm thick, robust stainless steel housing

•  integrated control unit

•  reusable cover for emergency exit switch made 

  out of Macrolon

Input

•  12-24V/DC supply

•  1x single remote opening

•  1x permanent remote opening 

•  2x holding magnet signals

•  1x door-too-long-open alarm

•  1x intrusion-alarm (or bridge), clamps briged = door

 closed

•  2x sabotage alarm

•  2x predefined brightnesses of LED

•  1x fire alarm control system (with bridge normal 

 operation)

•  1x emergency exit switch with internal fail safe

 contacts

•  1x reserve input

Output

•  2x holding magnet (electric escape route strikes)

•  1x RS-485 interface (bi-directional, half duplex) for 

 

  integration into building control systems

•  1x external sirène 24V, 0,5A OC

•  1x external flash light 24V, 0,5A OC

•  1x incident message relay (collective message) 

 

  30 V, 0,5 A

Conformity

This product complies with the essential requirements of 

the R&TTE guideline 1999/5/EG. The certificate of 

conformity you may request from your supplier.

Disposal

Dispose an obselet GfS Door Terminal at a a colleting 

point for electronic waste or at your supplier. Dispose 

the packaging material at a paper collecting point for 

paper resp. plastic. You may not dispose an obsolte 

device the general garbage.

Warrenty

Within the legal warrenty time we intend to repair all 

defect devices, whether the defect is caused by the 

material or assembly, or replace them. The warenty 

expires after a third-party repair.

Service

In case of a system failure or a defect GfS Door Terminal 

please contact the following address:

Содержание 790 000

Страница 1: ...Assembly Instruction GfS Door Terminal Safety on doors Part No 790 000 P a r t N o...

Страница 2: ...screws see hole pattern You can find the different measures on page 4 Connect all required cables Tighten the screws of the emergency exit button insertion positioned horizontally Tighten the screws...

Страница 3: ...control system with bridge normal operation 1x emergency exit switch with internal fail safe contacts 1x reserve input Output 2x holding magnet electric escape route strikes 1x RS 485 interface bi dir...

Страница 4: ...GfS Door Teminal Part No 790 000 4 790000_Ai_GfS Door_Terminal_1112_GB DIMENSION 240 198 10 72 90 42 20 60 80 80 15 50 41 98...

Страница 5: ...10 and 11 Opening command 12 GND Reference contact for door contact Signal GND 13 DC Contact Switch on GND resp bridge 12 and 13 Door closed 14 RS 485A Communication Data signals 15 RS 485B Communicat...

Страница 6: ...lowly twice and the GfS Door Terminal is activated again Precondition Holding magnet and door contact are closed When the door is opened during the opening time delay and no opening contact active the...

Страница 7: ...her 15 sec till conditions for activation are met blinks slowly green Door too long open If the door stays open for more than 15 sec an alarm Door too long open is triggered Every 3 secs the green LED...

Страница 8: ...in push pull The deactivation of the alarm only with key switch turn right possible blinks green Intrusion sabotage In case that one of the two feedback loops of the holding magnets or door contacts a...

Страница 9: ...ange orange orange 1x 1x 1x Change opening time Execute programming steps 1 3 Orange LED ring shines Programming mode opening time Start programming execute step 5 turn to the right Confirm programmin...

Страница 10: ...m to red silent alarm Execute programming step 7 in order to end the programming orange green on red off 1x 1x 1x store leave programm Automatic accoustic alarm switch off Execute programming step 1 3...

Страница 11: ...light Part No for the flash light of the GfS Door Terminal red 799 000 Replacement cover for emergency exit switch Part No for emergency exit switch of the GfS Door Terminal made out of unbrakeable Ma...

Страница 12: ...GfS Gesellschaft f r Sicherheitstechnik mbH Tempowerkring 15 21079 Hamburg Fon 0 40 79 01 95 0 Fax 0 40 79 01 95 11 info gfs online com www gfs online com Stamp 790000_Ai_GfS Door_Terminal_1112_GB...

Отзывы: