![gfm GF-Primo Dolly Скачать руководство пользователя страница 89](http://html1.mh-extra.com/html/gfm/gf-primo-dolly/gf-primo-dolly_instruction-manual-and-safety-manuallines_2219604089.webp)
88
15 Service
In general, maintenance should always be performed by qualified personnel in accordance with
relevant accident prevention regulations and generally accepted safety rules.
Recommended maintenance interval: 1 year
We recommend the owner / operator to a visual and functional test of the components listed below
several times a year, to make sure that the dolly system is in good condition.
Simple maintenance procedures are
Checking that all bolts et care secured correctly
Cleaning and occasionally oiling the guide bars
Monitoring the columns movement quality etc
Checking the wheel alignment and the gearbox performs smoothly
Maintaining clean track and studion wheels
Checking the adjustability and locked position of the wheel arms
Checking the wheel brakes as well as the brakes on the turnstile mount and column bearing
Monitoring the functionality of the electronic, hand control unit, (Emergency on/off switch, HCU
on/off, HCU control buttons and rocker switch, cable and wireless mode)
Checking the HCU battery and main dolly batteries
Intensive maintenance procedures are
Servicing the column
Attention:
Because the column is under pressure, should you need to service the
dolly, first ensure that the column is fully extended, to its maximum
height. Only then is it safe to start removing covers or dismantling the
column in any way.
Under no circumstances should any covers or housings be removed
before the column is fully extended!
When servicing the column inspect the following components:
Column cables
→
The cables should not be damaged or split
→
The cables must be tensioned properly (Turn the tension bolt fully until it ceases, then
reverse ¾ of a revolution)
Column bearings and guide bars
→
Keep clean and slightly lubricated with oil
Column drive belt
→
The drive belt, the motor’s drive pinion and drive pulley / plate must be undamaged,
clean and dry
→
The drive belt must be tensioned correctly (Using the 2 tension bolts, set the distance
between the motor holder and the mounting plate to 4-5mm)
Содержание GF-Primo Dolly
Страница 18: ...17 GF Primo s 3 steering modes and selector position...
Страница 20: ...19 GF Secondo s three steering modes and their selector positions...
Страница 27: ...26 Handle Rosette Battery cover Exchangeable HCU cover HCU battery Battery cover lock...
Страница 34: ...33 Key combination to change the channel Change the channel...
Страница 37: ...36...
Страница 42: ...41 Tastenkombination zum Kalibrieren des Dolly...
Страница 60: ...59 MARKERs 3 to 6 can be selected in the same manner Setting MARKERs...
Страница 68: ...67 Recording a sequence...
Страница 70: ...69...
Страница 88: ...87...