66
11.4.1.4.1 RECORD Mode
– Recording a movement sequence
Attention: Before recording, ensure that the complete liftrange of the column is clear from
obstructions.
Proceed as follows:
In NORMAL Mode, set the required RMP and SPD and move the column to the required
position e.g. 150mm.
Change to RECORD mode by pressing the mode selector button on the underneath of the
HCU.
By pressing the OPEN button a
„MOVE0000“file will be opened where the sequence will be
recorded.
Upon pressing the OPEN button the time bar will show in the top left-hand corner of the
display.
To start recording, press the Rocker Switch and proceed to drive the column as required. The
time bar will indicate the running time and you can record as much movement o ras many
stops as you wish.
INFO: During RECORD mode the RMP and SPD are adjusted by using the Rocker Switch
accordingly and not with the RMP and SPD buttons.
Press CLOSE to finish the recording. The sequence will be stored as file
„MOVE0000“
and a new file name
„MOVE0001“ for the recording of a new sequence.
Содержание GF-Primo Dolly
Страница 18: ...17 GF Primo s 3 steering modes and selector position...
Страница 20: ...19 GF Secondo s three steering modes and their selector positions...
Страница 27: ...26 Handle Rosette Battery cover Exchangeable HCU cover HCU battery Battery cover lock...
Страница 34: ...33 Key combination to change the channel Change the channel...
Страница 37: ...36...
Страница 42: ...41 Tastenkombination zum Kalibrieren des Dolly...
Страница 60: ...59 MARKERs 3 to 6 can be selected in the same manner Setting MARKERs...
Страница 68: ...67 Recording a sequence...
Страница 70: ...69...
Страница 88: ...87...