10

Signet 9900 Conductivity Transmitter 

ENTER

UP, DOWN keys

Scroll through Menu options or adjust values during editing
Press both together to exit a menu or escape without saving

RIGHT key

Select item or character to edit

ENTER key

Access menus
Save changes

ENTER

Open Collector (R1) 
Indicator LED

Mechanical Relay (R2)
Indicator LED

Backlight Sensor
(do not block)

Warning LED

Bar Graph

Units of Measure
(GPM, pH, sec, %, etc.)

Value

Label

Menu Indication

Menu Navigation Keys

Mechanical Relay (R3)
Indicator LED

All possible segments shown in this illustration. The instrument's software controls which segments are 
shown at any particular time. Only the bar graph and GF logo are visible when the unit is turned off.

Warning LED will be lit when No Sensor or Wrong Sensor is detected in Digital (S

3

L) mode.

Operation

Содержание Signet 9900

Страница 1: ...085 0 01 cm 1 316 SS electrode Sanitary Tri clamp fl ange 1 to 1 in 3 2820 1 198 844 000 0 1 cm 1 316 SS electrode in threads in line only 3 2821 1 198 844 001 1 0 cm 1 316 SS electrode in threads in...

Страница 2: ...l warranty and non warranty repairs being returned must include a fully completed Service Form and goods must be returned to your local GF Sales office or distributor Product returned without a Servic...

Страница 3: ...the plug inmodules may be installed either before or after the base unit is mounted If the 9900 Base Unit will be mounted using the wall mount accessory kit 3 9900 392 install plug in modules first I...

Страница 4: ...s provided to help guide the cutting process De burr and smooth the opening with a file 1 The panel mount transmitter is designed for installation using a DIN punch Recommended clearance on all sides...

Страница 5: ...and mechanical damage Seal the cable entry points to prevent moisture damage Only one wire should be inserted into a terminal Splice double wires outside the terminal or use appropriate wire ferrule...

Страница 6: ...o be used for system power 10 8 to 35 2 VDC NOTE Backlight LEDs Modbus and optional Relay Module do not operate on loop power Any connected sensors or sensor electronics that cannot operate on loop po...

Страница 7: ...s Module which Provides filtering and signal conditioning The standard sensor cable length can be extended up to 30 m 100 ft Loop Voltage DC Power Cond Res Module SHIELD TEMP WHT ISO GND BLK SIGNAL RE...

Страница 8: ...PNP Style Wiring The 9900 Open Collector R1 output provides high speed switching capability Signal frequencies can reach 400 pulses per minute The 9900 Open Collector R1 output connection is dependen...

Страница 9: ...d is often required to start editing Once entered correctly this password will not be needed for subsequent edits However once the menu system is exited the password will again be required when edit m...

Страница 10: ...hanical Relay R2 Indicator LED Backlight Sensor do not block Warning LED Bar Graph Units of Measure GPM pH sec etc Value Label Menu Indication Menu Navigation Keys Mechanical Relay R3 Indicator LED Al...

Страница 11: ...new value selection 6 Press or to select another menu item Repeat steps 3 5 as required 7 Press again to return to normal operation The menu is constructed in a loop so you can move forward and backw...

Страница 12: ...display LOOKING FOR If no sensor is attached to the 9900 the words TYPE and COND RES are displayed If the 9900 does not identify your sensor type correctly use the and keys to select your sensor type...

Отзывы: