Operating Manual MSA 330 /MSA 340
1 Introduction
5
1.3
Barcode Reader
When connected to the machine, it enables a quick insertion of welding
and operator parameters by reading the related bar code.
The scanner operates keeping it near to the barcode and pushing the
button.
The successful read is confirmed by an acoustic tone and a display
change.
If the bar code data is not identified immediately, repeat the reading.
To check if the barcode reader is damaged, you can try to read for test
purpose the code printed below, when the machine says ENTER FUSION
DATA
If this code is read successfully, the issue is not on the barcode reader.
After use, place the barcode reader into the protective case.
1.4
Extension Cables for Power Supply
To avoid excessive dissipation or brown out, on Extension cables, use
cables with section:
•
4mm² for cables
≤
10m full-run;
•
6mm² for cables
≤
30m full-run.