9 Maintenance
Operating Manual MSA 330 / MSA 340
34
9
Maintenance
9.1
Cleaning
Clean the unit regularly with a slightly damp cloth. The membrane
keyboard and other plates can be cleaned with industrial alcohol if
necessary (no solvents or Trichlor products).
Under no circumstances should the unit be sprayed or immersed in water
nor cleaned with compressed air.
9.2
Fusion cables
Regular control of the fusion cable is necessary. Damaged cable must
be replaced as well as the connector.
9.3
Function Check-up
Regular functional check-ups and readjustments are required. These
must be carried out by a Georg Fischer authorized service agent.
9.4
Spare parts
If repairs are necessary, please contact your local representative.
There is a separate spare parts list for ordering replacement parts.
Please indicate the following information:
•
Customer name.
•
Product description.
•
Machine type (code).
•
Part code (see the spare parts list)
•
Position of part into the spare parts draw.