2
2581 FlowtraMag
®
Meter
Refer to your local Georg Fischer Sales o
ffi
ce for the most
current warranty statement.
All warranty and non-warranty repairs being returned must
include a fully completed Service Form and goods must be
returned to your local GF Sales o
ffi
ce or distributor.
Product returned without a Service Form may not be
warranty replaced or repaired.
GF products with limited shelf-life (e.g. pH, ORP, chlorine
electrodes, calibration solutions; e.g. pH bu
ff
ers, turbidity
standards or other solutions) are warranted out of box but not
warranted against any damage, due to process or application
failures (e.g. high temperature, chemical poisoning, dry-out) or
mishandling (e.g. broken glass, damaged membrane, freezing
and/or extreme temperatures).
Chemical Compatibility
Warranty Information
Safety Information
Georg Fischer products are manufactured in a variety of wetted
materials to suit various liquids and chemicals.
All plastic materials including typical piping types (PVC) are more
or less permeable to contained media, such as water or volatile
substances, including some acids. This e
ff
ect is not related to
porosity, but purely a matter of gas di
ff
usion through the plastic.
If the plastic material is compatible with the medium according
to the application guidelines, the permeation will not damage
the plastic itself. However, if the plastic encloses other sensitive
components, as is the case with GF FlowtraMag meter, these
may be a
ff
ected or damaged by the media di
ff
using through the
plastic body.
Unit is factory shipped con
fi
gured to measure water.
1. Depressurize and vent system prior to installation or removal.
2. Con
fi
rm chemical compatibility before use.
3. DO NOT exceed maximum temperature or pressure specs.
4. ALWAYS wear safety goggles or face shield during
installation and/or service.
5. DO NOT alter product construction.
6. If this equipment is used in a manner not speci
fi
ed by the
manufacturer, the protection provided by the equipment may
be impaired
7. This device is not approved for use or installation in
hazardous locations.
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150
0.7
1.4
2.1
2.8
3.4
4.1
4.8
5.5
6.2
6.9
7.6
8.3
9.0
9.7
10.3
(bar)
(psi)
0
-20
0
20
40
60
80
100
°F
°C
-4
32
68
104
140
176
212
DN25 (1”)
DN40 (1.5”)
DN50 (2”)
DN80 (3”)
DN100(4”)
@ 3,5 bar
(51 psi)
@ 2,27 bar
(33 psi)
Operating Pressure/Temperature Graph
Caution / Warning / Danger
Indicates a potential hazard. Failure to follow all warnings
may lead to equipment damage, injury, or death
Electrocution Danger
Alerts user to risk of potential of injury or death via
electrocution.
Electrostatic Discharge (ESD)
Alerts user to risk of potential damage to product by ESD..
Personal Protective Equipment (PPE)
Always utilize the most appropriate PPE during
installation and service of GF products.
Pressurized System Warning
Sensor may be under pressure, take caution to vent
system prior to installation or removal. Failure to do so
may result in equipment damage and/or serious injury.
Hand Tighten Only
Overtightening may permanently damage product threads
and lead to failure. (union nut only)
Do Not Use Tools
Use of tool(s) may damage product beyond repair and
potentially void product warranty. (union nut only)
Note / Technical Notes
Highlights additional information or detailed procedure.
Hastelloy
®
is a registered trademark
of Haynes International.