19
2581 FlowtraMag
®
Meter
No calibration is necessary to begin using the 2581 FlowtraMag. The application and performance settings are pre-set to meet
the requirements of most applications. The FlowtraMag is shipped from the factory with the following calibration:
FlowtraMag
Model
K-Factor
pulse/L
K-Factor
pulse/Gal
Flow Rate
@20 mA L/min
Flow Rate
@20 mA Gal/min
DN25 (1 in.)
225.264
852.716
266.350
70.363
DN40 (1.5 in.)
90.588
342.912
662.340
174.972
DN50 (2 in.)
53.928
204.139
1112.600
293.920
DN80 (3 in.)
24.060
91.077
2493.760
658.781
DN100 (4 in.)
13.768
52.119
4357.800
1151.200
Calibration
Customization and Performance Settings
Application Note:
The unit is factory calibrated
for recommended setup.
See calibration certi
fi
cate for
complete details.
User has the option to
custom calibrate based on
their application.
USB
Windows PC
GND
Data
3-0252
2581
Output cable
Black
Brown
Shield
Blue not used
Not used
Ground (White)
Data (Red)
Bluetooth
®
set to S³L
iOS device with home button
Double click the home button. Find the minimized app and swipe up to close the app to clear the App Cache.
iOS device without home button
Swipe up from the bottom. Find the minimized App and swipe up to close the app to clear the App Cache.
For customization and performance settings, use the GF Con
fi
g Tool App or the Signet 0252 Con
fi
guration Tool and software.
Refer to the Signet 0252 Con
fi
guration Tool manual for details to adjust the following parameters:
4 to 20 mA span
: Factory setting is 4 mA = 0 and 20 mA = 10 m/s (32.8 ft/sec) equivalent
fl
ow rate, refer to the calibration table,
and can also be customized to any range.
Low Flow Cuto
ff
: Factory setting is 0.02 m/s (0.07 ft/s) equivalent
fl
ow rate, and can be customized to any user preferences.
Averaging Time
:
Factory setting is Low. Can be customized: O
ff
, Low, Med, High.
Sensitivity
:
Factory setting is 0.5 m/s (1.64 ft/s) equivalent
fl
ow rate, and can be customized to user preferences.
Close App