Mounting and fixing
GB 5
X
Install mounting plate with 2 x expanding rivet (
3.
).
X
Glue cable tie base (
4.
).
8.
7.
Fig.: 6.3.2
X
Lay platinum wire for electrical locking device GF (
5.
).
X
Connect platinum wire and electrical locking device GF with lustre terminals (
6.
).
à
Red-white wire to red-white
à
Red-blue wire to red-blue
X
Stow lustre terminals and cables in cover plate GF (
7.
).
X
Fix the cable with cable ties at the cable tie base (
8.
).
6.4 Connecting 24 V fixed-leaf cable
Fig.: 6.4.1
X
Route 24 V fixed-leaf cable of electrical hold-open device to the supply terminal (
1.
).
X
Shorten excess cable.
X
Connect cable to terminal (
2.
).
6.5 24 V Mains connection
Fig.: 6.5.1
X
Place the mains cable provided on site on the terminal (
1.
).
X
Shorten excess cable.
X
Connect cable to terminal (
2.
).
X
Secure the 24V mains cable and the 24V fixed-leaf cable with a cable tie to the tie base (
3.
).
Red =’+’
White = ’–’