TS 5000 E-ISM
GB 7
Mounting and securing
6.9 Positioning the function saveguard of the integrated closing sequence control
~30
mm
GF
3.
1.
2.
6.
4.
5.
4.
(~½ )
Fig.: 6.9.1
X
X
Pull out driver as far as possible (
1.
).
X
X
Loosen screws of stop rod (max. ½ rotation) (
2.
).
Stop rod may not pass under driver.
X
X
Pull out stop rod (
3.
).
à
Distance between edge block and stop is approx. 30 mm
X
X
Close moving leaf (
4.
).
Stop rod for function safeguard of the integrated closing sequence control is in position.
X
X
Open moving leaf (
5.
).
X
X
Tighten screws of stop rod (
6.
).
6.10 Adjusting electrical hold-open device
Moving leaf is shown.
Fig.: 6.10.1