![GEZE SecuLogic RWS TZ 300 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/geze/seculogic-rws-tz-300/seculogic-rws-tz-300_installation-and-commissioning-instructions-with-wiring-diagram_2219068021.webp)
SECULOGIC TZ300
21
Wiring diagram
Door control units
6.4
Latch
LED
Door
LED
Buzzer
Alarm LEDs
Tamper
switch
Emergency
button LED
Programming
interface
red
orange
blue
Door control unit TZ300 (terminals, fuses)
6.4.1
Fuse
Name
Value
Meaning
F1
1.5 A, SMF 125 V, quick-acting
24 V external
Operator control and display elements
Latch LED
à
Door LED
à
Alarm LED
à
Buzzer (75 dB at about 50 cm distance)
à
Technical specifications
Current consumption: 100mA
Supply voltage for external devices:
with standard PSU of the TZ300:
UP: NET220, max. 350 mA;
à
AP: NT19.2-24, max. 650 mA
with external PSU:
max. 800 mA (use only GEZE-approved PSUs)
à
Terminal assignment
Max. cable cross-section for screw and plug-in terminals: 1 mm²
Terminal Function
X103 blade terminal for GEZE
key switch
X100
red terminal field
1
Supply GND
3
24 V DC supply
X101
orange terminal field
5
Locking element, +, 24 V DC
6
Locking element, -, GND
14
Door locked feedback
15
Door closed feedback
2
24 V DC
2
24 V DC
9
Brief unlocking input
10
Emergency unlocking input
2
24 V DC
X102
Blue terminal field
2
24 V DC
22
NO, alarm output
Max. 1 A, 24 V DC
21
Com, alarm output
20
NC, alarm output
1
GND
Содержание SecuLogic RWS TZ 300