Preparing installation
6.2.6 Transom installation opposite hinge side with link arm
Hole pattern DIN left and DIN right reversed.
Fastening DIN right
Fastening DIN left
4
4
30
*
30
*
1
Dimensional reference centre of hinge
2
concealed line-feed possible in the hatched area, e.g. Ø 20 mm for the mains connection cable or low-voltage
connection (a side line-feed is also possible as an option, see chapter 7.2)
3
Directional arrow for precise positioning of the mounting plate
4
Hinge size 190 mm
*
With sensor adapter 35.5 mm
Fasteners
Steel/ aluminium doors
Timber doors
Drive fastening
8 countersunk screws M6 × 25 and riveting nut M6
8 wood screws Ø6 × 50
Fastening of link arm
2 cylinder head screws M6 × 20 and riveting nut M6
2 wood screws Ø6 × 30
Fastening of sensor adapter 2 countersunk screws M6 × 16 and riveting nut M6
2 wood screws Ø6 × 30
Space requirement and fastening of link arm
720
190
100
AV
Y
1
Y
2
Y
3
0
16
72
5
30
46
102
35
50
66
122
55
AV Spindle extension
42
Y
1
= 16 +
AV
Y
2
= 72 +
AV
10
10
22
LT
130
50
50
30*
8*
*
50
50
5
6
6
AV = 30
5
Base lower edge of lintel
6
Space requirement for sensors
*
With sensor adapter 35.5 mm
**
important functional dimension
LT
Reveal depth
Содержание Powerturn
Страница 50: ...Powerturn 50 Powerturn installation check list...
Страница 51: ...Powerturn 51 Powerturn installation check list...
Страница 52: ...Powerturn 52 Powerturn installation check list...
Страница 53: ...Powerturn 53 Powerturn installation check list...
Страница 54: ...Powerturn 54 Powerturn installation check list...
Страница 55: ...Powerturn 55 Powerturn installation check list...