Powerturn
10
Product description
5.2.3 Link arm
Standard link arm:
Sensor link arm (with link arm adapter):
5.2.4 Activation devices (accessories)
Refer to the wiring diagram for the Powerturn.
5.3 Types of installation
à
The opening angle of the door always has to be limited by a door stop.
à
Loads due to wind pressure, negative pressure or excess pressure must be taken into account.
à
The 2-leaf version corresponds to the 1-leaf type of installation.
à
We recommend the installation type involving link arms for the external doors.
The Powerturn allows the following types of installation, each in DIN left and DIN right:
5.3.1 Rail installation and link arm
Type of installation
Dimension
Powerturn
Powerturn F
Transom installation hinge side rail
Reveal depth LT [mm]
0–100
5)
(60–200)
1, 5)
0–100
Door overlap Ü [mm]
0–30
Max. door opening angle TÖW [°]
approx. 102–133
2)
Standard roller guide rail L = [mm]
691
Lever
L = [mm]
330
Hinge clearance [mm]
190
EN class /
Closing torque (at 0–4°) [Nm]
4–6 / 59 (70)
6)
Transom installation opposite hinge side rail
Reveal depth + door leaf thick-
ness [mm]
max. 100
Max. door opening angle TÖW [°]
approx. 108
3)
Standard roller guide rail L = [mm]
691
Lever
L = [mm]
450
Hinge clearance [mm]
190
EN class /
Closing torque (at 0–4°) [Nm]
4–6 / 63 (65)
6)
Содержание Powerturn
Страница 50: ...Powerturn 50 Powerturn installation check list...
Страница 51: ...Powerturn 51 Powerturn installation check list...
Страница 52: ...Powerturn 52 Powerturn installation check list...
Страница 53: ...Powerturn 53 Powerturn installation check list...
Страница 54: ...Powerturn 54 Powerturn installation check list...
Страница 55: ...Powerturn 55 Powerturn installation check list...