Powerdrive product family
24
Production test and commissioning
6.2.3 Connecting cover earthing
X
Connect the earthing cable (2) of the cover with the second plug-in connection of the device flat plug (1).
6.3 Mounting the safety devices
For information about connection and parameter setting of the safety sensors, and the inputs and outputs and
on commissioning, please refer to the wiring diagram.
X
Mount safety and activation equipment.
X
Route cables properly in cable ducts.
For electrical installation, see wiring diagram.
6.4 Installing operating elements/switches/push buttons
For electrical installation, see wiring diagram.
X
Mount the operating elements so that users cannot stand in the danger zones.
6.5 Commissioning the door system
For information about connection and parameter setting of the safety sensors, and the inputs and outputs and
on commissioning, please refer to the wiring diagram.
6.5.1 Creating the log book
X
Carry out a safety analysis.
X
Record installed options in the safety analysis for the operator.
6.6 Dismantling
WARNING!
Risk of injury!
People can be injured when the cover is handled.
X
Always make sure two people handle the cover.
CAUTION!
Risk of injury due to impact and crushing!
X
Secure the moving leaves against unintentional movement.
X
Disconnect the rechargeable battery.
Dismantling is done in the reverse order of installation.