Configuration program – wide-range reader GCLR 2000
GCLR-I 2000/GCLR-O 2000
18
5
Configuration program – wide-range reader GCLR 2000
Areas of application for the configuration program
The following settings can be made on the wide-range reader using the
configuration program:
à
Changing switching times for outputs relay 1 + 2
à
Delaying outputs relay 1 + 2
à
Activating keys for wireless transmission (HF)
à
Deactivating/activating programming keys GR.1 and GR.2 on the GCLR
Required accessories
The following software and hardware is required for connecting PC and
GCLR:
à
Program: Konfig_28.04.exe
Can be found in the download section of the GEZE website
à
Adapter USB 2.0 for serial no. 163520
5.1
Installing the configuration program
Administrator rights are necessary for installation.
Programs must be executed as the administrator.
5.1.1 Installing the adapter driver
The driver is included on the CD-ROM enclosed with the adapter.
X
Connect the adapter to the PC.
X
Save the program "Konfig.exe" to a local drive.
X
Start the program "Konfig.exe".
5.1.2 Setting up the serial interface
X
After starting the program, carry out the COM port settings in the menu
"Program" – "Init COM Port PC"
à
Interface:
Select COM port
à
Baud rate:
38400
à
Data bit:
8
à
Parity bit:
none
à
Stop bits:
1
à
Reception buffer:
2048
à
Transmission buffer:
2048
X
Confirm by pressing OK.
5.2
Main menu