Installation and commissioning.
GCLR-I 2000/GCLR-O 2000
10
4.2
Step 2: Connect the reader
Transponders are taught using group button 1 on the GCLR. Activation
of the door is via relay 1 of the GCLR through the respective input of the
connected peripherals. Other products not shown here can be connected to
relay 1 of the GCLR in the same way. Relay 1 switches as long as the
transponder is within the set scanned field + 2 seconds.
Option 1: Transponders which switch relay 2 can be taught using group
button 2. A transponder can also be taught in both groups.
The 2nd relay can be used either to realise the "accompany"
function or to activate a 2nd door.
Option 2: If DIP switch 4 is set to "ON", the relay only switches once for 2
seconds when the transponder is detected.
Option 3: If DIP switch 1 is set to "ON", an acoustic buzzer is enabled. This
sounds for the transponders taught in group 1 parallel to the
switching time of relay 1.
X
Heed the wiring diagrams and installation instructions of the respective
products.
à
The power supply NT is not required when the voltage supply to the
GCLR is via the drive.
X
Heed the overall current consumption.