![Gewiss GW68122 Скачать руководство пользователя страница 34](http://html.mh-extra.com/html/gewiss/gw68122/gw68122_user-and-installation-manual_2218842034.webp)
JOINON EASY electric vehicle recharging unit
34
Connection procedure
1. Open the casing as shown in the figure.
1
2
3
GW 52 401
2. Drill the back-mounting box using a multi-diameter drill (not supplied) at the top or the bottom as required.
1
2
3
GW 52 401
3. Connect the power supply cable to the input terminal block, then tighten the cable using the cable gland.
L1 L2 L3 N PE
4. Once the electrical system is complete, the system is ready to be turned on. Make sure the miniature circuit
breaker installed inside the station is in position “1”.
If the station identifies a malfunction, the light will turn red.